{"title":"Torque \u0026 Prosthetic Kits","description":"","products":[{"product_id":"universal-torque-wrench-with-8-drivers-surgident","title":"Surgident Universal Torque Wrench with 8 Drivers","description":"\u003ch3\u003e\u003cstrong\u003eUniversal Torque Wrench with 8 drivers - SURGIDENT®\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eSmart Solution for safe-finish of implant prosthetics. Surgeons are able to reach deep molar areas without difficulty compared to other torque drivers\u003c\/p\u003e","brand":"Surgident","offers":[{"title":"Default Title","offer_id":49137964876066,"sku":"SD-STOQ","price":1400.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/SD-STOQ_1.jpg?v=1732278834"},{"product_id":"universal-torque-wrench-surgident","title":"Surgident Universal Torque Wrench","description":"\u003cdiv\u003e\n    \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/Hero-Surgident_UniversalTorqueWrench.png?v=1782275568\" style=\"display:block;max-width:100%;justify-self:center;\" alt=\"Surgident SD-TQ Universal Torque Wrench\"\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── HERO ──────────────────────────────────────────────────── --\u003e\n  \u003cdiv class=\"pd-hero\"\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv class=\"pd-hero-tag\"\u003eSurgident · Implant Prosthetic Instrument\u003c\/div\u003e\n      \u003ch1 class=\"pd-hero-title\"\u003eSD-TQ\u003cbr\u003eUniversal Torque Wrench\u003c\/h1\u003e\n      \u003cp class=\"pd-hero-sub\"\u003e\n        The SD-TQ is a universal torque wrench for fixing and separating upper implant structures, offering\n        guaranteed tightening precision whatever the type of implant connection or difficulty of access. Its\n        angular head design reaches the molar area where conventional wrenches cannot, with a selectable torque\n        range of 5–35 N\/cm and an audible click when the set value is met.\n      \u003c\/p\u003e\n      \u003cdiv class=\"pd-hero-badges\"\u003e\n        \u003cspan class=\"pd-hero-badge\"\u003e\n          \u003csvg viewbox=\"0 0 16 16\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.8\"\u003e\n            \u003ccircle cx=\"8\" cy=\"8\" r=\"6.5\"\u003e\u003c\/circle\u003e\n            \u003cpath d=\"M5 8.5l2 2 4-4\"\u003e\u003c\/path\u003e\n          \u003c\/svg\u003e\n          Torque Range 5–35 N\/cm\n        \u003c\/span\u003e\n        \u003cspan class=\"pd-hero-badge\"\u003e\n          \u003csvg viewbox=\"0 0 16 16\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.8\"\u003e\n            \u003cpath d=\"M3 12l4-4 3 3 4-5\"\u003e\u003c\/path\u003e\n          \u003c\/svg\u003e\n          Autoclave Compatible\n        \u003c\/span\u003e\n        \u003cspan class=\"pd-hero-badge\"\u003e\n          \u003csvg viewbox=\"0 0 16 16\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.8\"\u003e\n            \u003cpath d=\"M8 2v12M2 8h12\"\u003e\u003c\/path\u003e\n          \u003c\/svg\u003e\n          Short \u0026amp; Long 1.2mm Drivers Included\n        \u003c\/span\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── INDICATIONS ───────────────────────────────────────────── --\u003e\n  \u003cdiv class=\"pd-section\"\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv class=\"pd-label\"\u003eIndications\u003c\/div\u003e\n      \u003ch2 class=\"pd-h2\"\u003eWhen to use the SD-TQ\u003c\/h2\u003e\n      \u003cp class=\"pd-lead\"\u003eThe SD-TQ is designed for prosthetic tightening and loosening across any implant\n        connection type, including hard-to-access posterior sites.\u003c\/p\u003e\n\n      \u003cdiv class=\"use-grid\"\u003e\n\n        \u003cdiv class=\"use-item\"\u003e\n          \u003cdiv class=\"use-icon\"\u003e\n            \u003csvg viewbox=\"0 0 20 20\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.6\"\u003e\n              \u003cpath d=\"M10 3v14M4 10h12\"\u003e\u003c\/path\u003e\n            \u003c\/svg\u003e\n          \u003c\/div\u003e\n          \u003cdiv class=\"use-text\"\u003e\n\u003cstrong\u003eProsthetic Screw Tightening\u003c\/strong\u003e — Fixing upper structures to\n            implants with precise, repeatable torque at the set value.\u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"use-item\"\u003e\n          \u003cdiv class=\"use-icon\"\u003e\n            \u003csvg viewbox=\"0 0 20 20\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.6\"\u003e\n              \u003cpath d=\"M4 10h12M7 6l-4 4 4 4\"\u003e\u003c\/path\u003e\n            \u003c\/svg\u003e\n          \u003c\/div\u003e\n          \u003cdiv class=\"use-text\"\u003e\n\u003cstrong\u003eProsthetic Screw Loosening\u003c\/strong\u003e — Safely separating and removing\n            upper structures during recall, maintenance, or prosthetic revision appointments.\u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"use-item\"\u003e\n          \u003cdiv class=\"use-icon\"\u003e\n            \u003csvg viewbox=\"0 0 20 20\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.6\"\u003e\n              \u003cpath d=\"M10 4a6 6 0 100 12A6 6 0 0010 4z\"\u003e\u003c\/path\u003e\n              \u003cpath d=\"M14 14l3 3\"\u003e\u003c\/path\u003e\n            \u003c\/svg\u003e\n          \u003c\/div\u003e\n          \u003cdiv class=\"use-text\"\u003e\n\u003cstrong\u003eMolar \u0026amp; Posterior Access\u003c\/strong\u003e — Angular head design reaches\n            the molar area that is difficult or impossible to access with a conventional straight wrench.\u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"use-item\"\u003e\n          \u003cdiv class=\"use-icon\"\u003e\n            \u003csvg viewbox=\"0 0 20 20\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.6\"\u003e\n              \u003crect x=\"3\" y=\"5\" width=\"14\" height=\"10\" rx=\"2\"\u003e\u003c\/rect\u003e\n              \u003cpath d=\"M7 5V3m6 2V3\"\u003e\u003c\/path\u003e\n            \u003c\/svg\u003e\n          \u003c\/div\u003e\n          \u003cdiv class=\"use-text\"\u003e\n\u003cstrong\u003eUniversal Implant Compatibility\u003c\/strong\u003e — Suitable for use with\n            any implant connection type, regardless of system or platform.\u003c\/div\u003e\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── FEATURE HIGHLIGHTS ────────────────────────────────────── --\u003e\n  \u003cdiv class=\"pd-section pd-section--muted\"\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv class=\"pd-label\"\u003eFeatures\u003c\/div\u003e\n      \u003ch2 class=\"pd-h2\"\u003eDesigned for precise, safe prosthetic finishing\u003c\/h2\u003e\n      \u003cp class=\"pd-lead\"\u003eEvery detail of the SD-TQ is built to support reliable, repeatable tightening — whether\n        in an open anterior site or a confined posterior access.\u003c\/p\u003e\n\n      \u003cdiv class=\"detail-grid\" style=\"margin-top:32px;\"\u003e\n\n        \u003cdiv class=\"detail-item\"\u003e\n          \u003cdiv class=\"detail-media\"\u003e\n            \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/SD-TQ_Feature_1.png?v=1782275782\" alt=\"SD-TQ installation — latch key and driver insertion\"\u003e\n          \u003c\/div\u003e\n          \u003cdiv\u003e\n            \u003cdiv class=\"detail-title\"\u003eInstallation\u003c\/div\u003e\n            \u003cdiv class=\"detail-desc\"\u003e\n              \u003cp\u003eTurn the handle clockwise or counterclockwise to tighten or loosen the screw. The wrench sounds\n                \"clack\" when the set torque value is met — confirming correct, consistent tightening every\n                time.\u003c\/p\u003e\n            \u003c\/div\u003e\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"detail-item\"\u003e\n          \u003cdiv class=\"detail-media\"\u003e\n            \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/SD-TQ_Feature_2_autoclave.png?v=1782275788\" alt=\"SD-TQ autoclave — head separates from body for sterilization\"\u003e\n          \u003c\/div\u003e\n          \u003cdiv\u003e\n            \u003cdiv class=\"detail-title\"\u003eAutoclave OK\u003c\/div\u003e\n            \u003cdiv class=\"detail-desc\"\u003e\n              \u003cp\u003eThe head can be fully separated from the body for sterilization — supporting standard\n                autoclave protocols without the need for separate disposable components.\u003c\/p\u003e\n            \u003c\/div\u003e\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"detail-item\"\u003e\n          \u003cdiv class=\"detail-media\"\u003e\n            \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/SD-TQ_Feature_3_selector.png?v=1782275568\" alt=\"SD-TQ torque selector knob 5 to 35 N\/cm\"\u003e\n          \u003c\/div\u003e\n          \u003cdiv\u003e\n            \u003cdiv class=\"detail-title\"\u003eTorque Selector\u003c\/div\u003e\n            \u003cdiv class=\"detail-desc\"\u003e\n              \u003cp\u003eEasy torque setting across a 5–35 N\/cm range. Rotate the selector at the base of the body\n                to the required value before tightening — no additional tools required.\u003c\/p\u003e\n            \u003c\/div\u003e\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"detail-item\"\u003e\n          \u003cdiv class=\"detail-media\"\u003e\n            \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/SD-TQ_Feature_4_oilhole.png?v=1782275569\" alt=\"SD-TQ oil hole for handpiece lubrication\"\u003e\n          \u003c\/div\u003e\n          \u003cdiv\u003e\n            \u003cdiv class=\"detail-title\"\u003eOil Hole\u003c\/div\u003e\n            \u003cdiv class=\"detail-desc\"\u003e\n              \u003cp\u003eInject handpiece oil into the hole on the bottom of the body before and after each use to\n                maintain mechanism performance and extend the service life of the wrench.\u003c\/p\u003e\n            \u003c\/div\u003e\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── WHAT'S INCLUDED ───────────────────────────────────────── --\u003e\n  \u003cdiv class=\"pd-section\"\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv style=\"border-radius:12px;overflow:hidden;line-height:0;\"\u003e\n        \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/SD-TQ_overview.png?v=1782275936\" style=\"display:block;width:100%;max-width:100%;\" alt=\"Surgident Universal Torque Wrench\"\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv class=\"pd-label\"\u003eWhat's Included\u003c\/div\u003e\n      \u003ch2 class=\"pd-h2\"\u003eKit contents\u003c\/h2\u003e\n      \u003cp class=\"pd-lead\"\u003eThe SD-TQ ships with both Short and Long 1.2mm drivers for immediate clinical use.\u003c\/p\u003e\n\n      \u003cdiv class=\"kit-table-wrap\"\u003e\n        \u003ctable class=\"kit-table\"\u003e\n          \u003cthead\u003e\n            \u003ctr\u003e\n              \u003cth\u003eComponent\u003c\/th\u003e\n              \u003cth\u003eDetail\u003c\/th\u003e\n              \u003cth\u003eQ'ty\u003c\/th\u003e\n            \u003c\/tr\u003e\n          \u003c\/thead\u003e\n          \u003ctbody\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eSD-TQ Universal Torque Wrench\u003c\/td\u003e\n              \u003ctd\u003eAngular head, stable grip, torque selector 5–35 N\/cm, oil hole, autoclavable head\u003c\/td\u003e\n              \u003ctd\u003e1\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eDriver — Short\u003c\/td\u003e\n              \u003ctd\u003e1.2mm diameter · 23.5mm length\u003c\/td\u003e\n              \u003ctd\u003e1\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eDriver — Long\u003c\/td\u003e\n              \u003ctd\u003e1.2mm diameter · 30mm length\u003c\/td\u003e\n              \u003ctd\u003e1\u003c\/td\u003e\n            \u003c\/tr\u003e\n          \u003c\/tbody\u003e\n        \u003c\/table\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── SPECIFICATIONS ─────────────────────────────────────────── --\u003e\n  \u003cdiv class=\"pd-section pd-section--muted\"\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv class=\"pd-label\"\u003eSpecifications\u003c\/div\u003e\n      \u003ch2 class=\"pd-h2\"\u003eTechnical specifications\u003c\/h2\u003e\n\n      \u003ctable class=\"spec-table\"\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eDevice type\u003c\/td\u003e\n          \u003ctd\u003eUniversal prosthetic torque wrench — angular head\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eTorque range\u003c\/td\u003e\n          \u003ctd\u003e5–35 N\/cm (selectable)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eTorque indication\u003c\/td\u003e\n          \u003ctd\u003eAudible \"clack\" when set torque value is reached\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eDriver diameter\u003c\/td\u003e\n          \u003ctd\u003e1.2mm\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eShort driver length\u003c\/td\u003e\n          \u003ctd\u003e23.5mm\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eLong driver length\u003c\/td\u003e\n          \u003ctd\u003e30mm\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eSterilization\u003c\/td\u003e\n          \u003ctd\u003eAutoclave compatible — head separates from body\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eManufacturer\u003c\/td\u003e\n          \u003ctd\u003eSurgident\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eOrigin\u003c\/td\u003e\n          \u003ctd\u003eMade in Korea\u003c\/td\u003e\n        \u003c\/tr\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── OPERATING TIPS ────────────────────────────────────────── --\u003e\n  \u003cdiv class=\"pd-section\"\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv class=\"pd-label\"\u003eOperating Tips\u003c\/div\u003e\n      \u003ch2 class=\"pd-h2\"\u003eGetting the most from the SD-TQ\u003c\/h2\u003e\n      \u003cp class=\"pd-lead\"\u003ePractical guidance for consistent tightening and proper maintenance.\u003c\/p\u003e\n\n      \u003cdiv class=\"tips-list\"\u003e\n        \u003cdiv class=\"tip-item\"\u003e\n          \u003cdiv class=\"tip-num\"\u003e1\u003c\/div\u003e\n          \u003cdiv class=\"tip-body\"\u003e\n\u003cstrong\u003eSet the torque selector before placing the driver.\u003c\/strong\u003e Rotate\n            the selector at the base of the wrench to the required value (5–35 N\/cm) before engaging the\n            driver with the screw. Setting the torque after the driver is in position risks an accidental\n            partial turn.\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"tip-item\"\u003e\n          \u003cdiv class=\"tip-num\"\u003e2\u003c\/div\u003e\n          \u003cdiv class=\"tip-body\"\u003e\n\u003cstrong\u003eInstall the driver correctly before use.\u003c\/strong\u003e Turn the latch key\n            to the right, insert the 1.2mm driver into the hole, then return the latch key to lock. Confirm\n            the driver is seated securely before beginning tightening — a loose driver reduces torque accuracy\n            and risks cam-out damage to the screw head.\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"tip-item\"\u003e\n          \u003cdiv class=\"tip-num\"\u003e3\u003c\/div\u003e\n          \u003cdiv class=\"tip-body\"\u003e\n\u003cstrong\u003eStop turning immediately when you hear the \"clack\".\u003c\/strong\u003e The\n            audible click confirms the set torque value has been reached. Continuing to turn after the click\n            bypasses the torque-limiting mechanism and risks overtightening the prosthetic screw.\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"tip-item\"\u003e\n          \u003cdiv class=\"tip-num\"\u003e4\u003c\/div\u003e\n          \u003cdiv class=\"tip-body\"\u003e\n\u003cstrong\u003eUse the Long driver for molar and posterior sites.\u003c\/strong\u003e The Short\n            driver (23.5mm) is suited to anterior and premolar positions with good access. The Long driver\n            (30mm) gives the additional reach needed for posterior molar sites where the wrench body must\n            clear adjacent dentition.\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"tip-item\"\u003e\n          \u003cdiv class=\"tip-num\"\u003e5\u003c\/div\u003e\n          \u003cdiv class=\"tip-body\"\u003e\n\u003cstrong\u003eOil the wrench before and after every use.\u003c\/strong\u003e Inject handpiece\n            oil into the oil hole on the bottom of the body before and after each use. Regular lubrication\n            maintains the internal mechanism, prevents premature wear, and ensures the torque selector remains\n            accurate over time.\u003c\/div\u003e\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"tip-warn\"\u003e\n        \u003cstrong\u003e⚠ Operating Notice:\u003c\/strong\u003e The SD-TQ is a prosthetic torque wrench intended for use by\n        trained dental professionals. Do not exceed the set torque value — overtightening may fracture the\n        prosthetic screw. Autoclave only the head component; refer to the manufacturer's sterilization\n        instructions for the body. Refer to the Instructions for Use for full handling, maintenance, and\n        safety information.\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e","brand":"Surgident","offers":[{"title":"Default Title","offer_id":49137966022946,"sku":"SD-TQ","price":1000.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/SD-TQ-1.png?v=1732062757"},{"product_id":"universal-implant-prosthetic-kit-with-torque-wrench","title":"Surgident Universal Implant Prosthetic Kit with Torque Wrench","description":"\u003ch3\u003e\u003cstrong\u003eImplant Prosthetic Driver Kit\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe implant prosthetic driver kit is used to fasten or remove implant prosthetics of all types. This kit is compatible with the majority of implant systems. The drivers provided have a contra-angle slowspeed connection and are able to be used with the wrench as well as with any slow speed implant handpiece. This kit also provides a thumb knob for hand-held use. The implant prosthetic driver kit gives clinicians the ability to restore the vast majority of cases due to the variety of drivers provided.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSizes Provided\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA short and long driver are provided for the styles listed above. The length of the short and long drivers are 23.5mm and 30mm respectively.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuality Manufacturing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis product is manufacturer by one of the largest and most reputable manufacturing firms in South Korea. Their attention to detail and commitment to using quality materials ensures that their products remain reliable long-term.\u003c\/p\u003e","brand":"Surgident","offers":[{"title":"Default Title","offer_id":49137967399202,"sku":"SD-IPD2","price":900.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/SDIPD2.png?v=1732279505"},{"product_id":"universal-prosthetic-kit","title":"NeoBiotech Universal Prosthetic Kit","description":"  \u003cdiv\u003e\n    \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/UniversalKit-Hero.png?v=1785904027\" style=\"display:block;max-width:100%;justify-self:center;\" alt=\"Neobiotech Universal Prosthetic Kit — prosthetic drivers compatible with major implant brands\"\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── HERO ──────────────────────────────────────────────────── --\u003e\n  \u003cdiv class=\"pd-hero\"\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv class=\"pd-hero-tag\"\u003eNeobiotech · Prosthetic Solution\u003c\/div\u003e\n      \u003ch1 class=\"pd-hero-title\"\u003eUniversal\u003cbr\u003eProsthetic Kit\u003c\/h1\u003e\n      \u003cp class=\"pd-hero-sub\"\u003e\n        A complete set of prosthetic drivers compatible with Straumann, Nobel Biocare, Osstem,\n        Zimmer, Astra, Neobiotech, and more, covering the implant brands most commonly\n        encountered in Australian dental practice, in a single organised tray. No need to\n        purchase separate driver kits for each system. Four driver types, two lengths each,\n        plus a Driver Holder and Torque Ratchet for a complete chairside prosthetic workflow.\n      \u003c\/p\u003e\n      \u003cdiv class=\"pd-hero-badges\"\u003e\n        \u003cspan class=\"pd-hero-badge\"\u003e\n          \u003csvg viewbox=\"0 0 16 16\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.8\"\u003e\n            \u003ccircle cx=\"8\" cy=\"8\" r=\"6.5\"\u003e\u003c\/circle\u003e\n            \u003cpath d=\"M5 8.5l2 2 4-4\"\u003e\u003c\/path\u003e\n          \u003c\/svg\u003e\n          Straumann · Nobel · Osstem · Zimmer · Astra \u0026amp; More\n        \u003c\/span\u003e\n        \u003cspan class=\"pd-hero-badge\"\u003e\n          \u003csvg viewbox=\"0 0 16 16\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.8\"\u003e\n            \u003cpath d=\"M3 12l4-4 3 3 4-5\"\u003e\u003c\/path\u003e\n          \u003c\/svg\u003e\n          One Kit — No Per-Brand Driver Sets Required\n        \u003c\/span\u003e\n        \u003cspan class=\"pd-hero-badge\"\u003e\n          \u003csvg viewbox=\"0 0 16 16\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.8\"\u003e\n            \u003cpath d=\"M8 2v12M2 8h12\"\u003e\u003c\/path\u003e\n          \u003c\/svg\u003e\n          Driver Holder · Torque Ratchet Included\n        \u003c\/span\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── CLINICAL INSIGHT ──────────────────────────────────────── --\u003e\n  \u003cdiv class=\"pd-section\"\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv class=\"pd-label\"\u003eClinical Insight\u003c\/div\u003e\n      \u003ch2 class=\"pd-h2\"\u003eWhat clinicians are saying\u003c\/h2\u003e\n      \u003cp class=\"pd-lead\"\u003eReal-world feedback from implantologists and prosthodontists using the\n        Universal Prosthetic Kit in multi-brand practice environments.\u003c\/p\u003e\n\n      \u003cdiv class=\"insights-grid\"\u003e\n        \u003cdiv class=\"insight-card\"\u003e\n          \u003cp class=\"insight-quote\"\u003e\n            \"In my practice I see patients who've had implants placed elsewhere — Straumann,\n            Nobel, Osstem, you name it. Before this kit I was constantly checking which\n            driver set to pull out of the cupboard, or worse, realising mid-appointment that\n            I didn't have the right one. Having all four driver types in one tray has\n            completely removed that problem. It sounds like a small thing, but it adds up\n            to real time saved across a full day of restorative appointments.\"\n          \u003c\/p\u003e\n          \u003cdiv class=\"insight-tag\"\u003eMulti-Brand · Workflow Efficiency · Restorative Practice\u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"insight-card\"\u003e\n          \u003cp class=\"insight-quote\"\u003e\n            \"The economics of maintaining separate prosthetic driver kits for every implant\n            brand your patients might present with is genuinely significant — especially\n            when patients transfer from interstate or overseas. The Universal Prosthetic Kit\n            covers Straumann SCS, Nobel Unigrip, and all the standard hex connections in\n            one set that lives permanently on my prosthetic tray. It's paid for itself many\n            times over.\"\n          \u003c\/p\u003e\n          \u003cdiv class=\"insight-tag\"\u003eCost Efficiency · SCS · Unigrip · Multi-Brand Coverage\u003c\/div\u003e\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── INDICATIONS ───────────────────────────────────────────── --\u003e\n  \u003cdiv class=\"pd-section pd-section--muted\"\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv class=\"pd-label\"\u003eIndications\u003c\/div\u003e\n      \u003ch2 class=\"pd-h2\"\u003eWhen to use the Universal Prosthetic Kit\u003c\/h2\u003e\n      \u003cp class=\"pd-lead\"\u003eIndicated for all prosthetic stages of implant treatment where abutment\n        or screw tightening and removal is required. One kit eliminates the need to purchase\n        and maintain separate driver sets for each implant brand in your practice.\u003c\/p\u003e\n\n      \u003cdiv class=\"use-grid\"\u003e\n\n        \u003cdiv class=\"use-item\"\u003e\n          \u003cdiv class=\"use-icon\"\u003e\n            \u003csvg viewbox=\"0 0 20 20\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.6\"\u003e\n              \u003cpath d=\"M10 3c0 0-5 3-5 8a5 5 0 0010 0c0-5-5-8-5-8z\"\u003e\u003c\/path\u003e\n              \u003cpath d=\"M10 11v3M8 13h4\"\u003e\u003c\/path\u003e\n            \u003c\/svg\u003e\n          \u003c\/div\u003e\n          \u003cdiv class=\"use-text\"\u003e\n\u003cstrong\u003eCover Screw Placement and Removal\u003c\/strong\u003e — Connecting\n            and detaching cover screws at implant placement and second-stage surgery, across\n            all compatible implant systems.\u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"use-item\"\u003e\n          \u003cdiv class=\"use-icon\"\u003e\n            \u003csvg viewbox=\"0 0 20 20\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.6\"\u003e\n              \u003cpath d=\"M4 16l4-4 4 4 4-6\"\u003e\u003c\/path\u003e\n            \u003c\/svg\u003e\n          \u003c\/div\u003e\n          \u003cdiv class=\"use-text\"\u003e\n\u003cstrong\u003eAbutment Screw Tightening\u003c\/strong\u003e — Final seating and\n            torque-controlled tightening of abutment screws at the restorative stage, using\n            the Torque Ratchet for accurate torque delivery.\u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"use-item\"\u003e\n          \u003cdiv class=\"use-icon\"\u003e\n            \u003csvg viewbox=\"0 0 20 20\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.6\"\u003e\n              \u003cpath d=\"M3 17l4-8 3 4 2-6 4 10\"\u003e\u003c\/path\u003e\n            \u003c\/svg\u003e\n          \u003c\/div\u003e\n          \u003cdiv class=\"use-text\"\u003e\n\u003cstrong\u003eHealing Abutment Connection\u003c\/strong\u003e — Placing and\n            retrieving healing abutments at second-stage surgery, using the Driver Holder for\n            intraoral access.\u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"use-item\"\u003e\n          \u003cdiv class=\"use-icon\"\u003e\n            \u003csvg viewbox=\"0 0 20 20\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.6\"\u003e\n              \u003crect x=\"3\" y=\"5\" width=\"14\" height=\"10\" rx=\"2\"\u003e\u003c\/rect\u003e\n              \u003cpath d=\"M3 9h14\"\u003e\u003c\/path\u003e\n            \u003c\/svg\u003e\n          \u003c\/div\u003e\n          \u003cdiv class=\"use-text\"\u003e\n\u003cstrong\u003eMulti-Brand Practice Environments\u003c\/strong\u003e — A single Universal Prosthetic Kit\n            covers the driver requirements for major implant systems including Straumann, Nobel Biocare, Osstem,\n            Southern Implants, and more, removing the need to purchase and maintain separate per-brand driver kits.\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"use-item\"\u003e\n          \u003cdiv class=\"use-icon\"\u003e\n            \u003csvg viewbox=\"0 0 20 20\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.6\"\u003e\n              \u003cpath d=\"M10 4a6 6 0 100 12A6 6 0 0010 4zM10 4v2M10 14v2M4 10H2M18 10h-2\"\u003e\u003c\/path\u003e\n            \u003c\/svg\u003e\n          \u003c\/div\u003e\n          \u003cdiv class=\"use-text\"\u003e\n\u003cstrong\u003eUpper Structure Connection and Removal\u003c\/strong\u003e — Connecting\n            or detaching any other upper prosthetic structures placed on the implant fixture,\n            at any stage of implant treatment.\u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"use-item\"\u003e\n          \u003cdiv class=\"use-icon\"\u003e\n            \u003csvg viewbox=\"0 0 20 20\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.6\"\u003e\n              \u003cpath d=\"M5 15l3-6 2 3 2-5 3 8\"\u003e\u003c\/path\u003e\n              \u003cpath d=\"M3 17h14\"\u003e\u003c\/path\u003e\n            \u003c\/svg\u003e\n          \u003c\/div\u003e\n          \u003cdiv class=\"use-text\"\u003e\n\u003cstrong\u003eTorque Verification and Re-tightening\u003c\/strong\u003e — Recall\n            and maintenance appointments where abutment or prosthetic screw torque is verified\n            or re-applied using the Torque Ratchet Wrench.\u003c\/div\u003e\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── KIT COMPONENTS ───────────────────────────────────────── --\u003e\n  \u003cdiv class=\"pd-section pd-section--muted\"\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv class=\"pd-label\"\u003eKit Components\u003c\/div\u003e\n      \u003ch2 class=\"pd-h2\"\u003eComplete instrument set\u003c\/h2\u003e\n      \u003cp class=\"pd-lead\"\u003eAll prosthetic drivers, a Driver Holder, and a Torque Ratchet —\n        supplied in a single organised tray (Neo Universal Prosthetic Kit Ver.0).\u003c\/p\u003e\n\n      \u003cdiv style=\"margin: 24px 0 32px; background:#fff; border-radius:12px; padding:16px; border:1px solid var(--c-border);\"\u003e\n        \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/UniversalKit-Component_1.png?v=1785904592\" style=\"display:block;width:100%;max-width:100%;\" alt=\"Universal Prosthetic Kit tray — 4 driver types in 10mm and 15mm, Torque Ratchet Wrench, and Driver Holder\"\u003e\n      \u003c\/div\u003e\n\n      \u003c!-- 1. Driver --\u003e\n      \u003ch3 style=\"font-size:1em;font-weight:700;color:var(--c-text);margin-bottom:4px;\"\u003e1. Driver\u003c\/h3\u003e\n      \u003cp class=\"kit-note\" style=\"margin-top:0;margin-bottom:12px;\"\u003eUsed to tighten an abutment or\n        abutment screw. Each driver type is supplied in both 10mm (short) and 15mm (long) versions.\u003c\/p\u003e\n\n      \u003cdiv class=\"kit-table-wrap\"\u003e\n        \u003ctable class=\"kit-table\"\u003e\n          \u003cthead\u003e\n            \u003ctr\u003e\n              \u003cth\u003eDriver Type\u003c\/th\u003e\n              \u003cth\u003eKey Spec\u003c\/th\u003e\n              \u003cth\u003eCompatible Implant Systems\u003c\/th\u003e\n            \u003c\/tr\u003e\n          \u003c\/thead\u003e\n          \u003ctbody\u003e\n            \u003ctr\u003e\n              \u003ctd\u003e1.2 Hex Driver (0.48\")\u003cbr\u003e\u003cspan style=\"font-size:0.85em; font-weight:400; color:#555;\"\u003eHD1210S ·\n                  HD1215S\u003c\/span\u003e\n\u003c\/td\u003e\n              \u003ctd\u003e10mm · 15mm\u003c\/td\u003e\n              \u003ctd\u003eNeobiotech \/ Biomet 3i \/ Dentsply-Friadent \/ Xive \/ Osstem \/ DIO \/ Megagen\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003e1.25 Hex Driver (0.5\")\u003cbr\u003e\u003cspan style=\"font-size:0.85em; font-weight:400; color:#555;\"\u003eHD12510S ·\n                  HD12515S\u003c\/span\u003e\n\u003c\/td\u003e\n              \u003ctd\u003e10mm · 15mm\u003c\/td\u003e\n              \u003ctd\u003eBiohorizons \/ Zimmer \/ Astra \/ Implant Direct Legacy \/ Camlog \/ MIS \/ Dentis \/ Dentium\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eSCS Driver\u003cbr\u003e\u003cspan style=\"font-size:0.85em; font-weight:400; color:#555;\"\u003eWSCSD10S · WSCSD15S\u003c\/span\u003e\n              \u003c\/td\u003e\n              \u003ctd\u003e10mm · 15mm\u003c\/td\u003e\n              \u003ctd\u003eStraumann \/ Implant Direct Replant\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eUnigrip Driver\u003cbr\u003e\u003cspan style=\"font-size:0.85em; font-weight:400; color:#555;\"\u003eWUGD10S ·\n                  WUGD15S\u003c\/span\u003e\n\u003c\/td\u003e\n              \u003ctd\u003e10mm · 15mm\u003c\/td\u003e\n              \u003ctd\u003eNobel Biocare \/ Implant Direct Swishplait \/ Southern Implants \/ Neoss\u003c\/td\u003e\n            \u003c\/tr\u003e\n          \u003c\/tbody\u003e\n        \u003c\/table\u003e\n      \u003c\/div\u003e\n\n      \u003c!-- 2. Driver Holder --\u003e\n      \u003ch3 style=\"font-size:1em;font-weight:700;color:var(--c-text);margin-top:32px;margin-bottom:4px;\"\u003e2. Driver Holder\n         \u003cspan style=\"font-weight:400;color:#555;font-size:0.9em;\"\u003eDH01\u003c\/span\u003e\n\u003c\/h3\u003e\n      \u003cp class=\"kit-note\" style=\"margin-top:0;margin-bottom:12px;\"\u003eConnects to various prosthetic\n        drivers to allow easy intraoral handling of healing cover screws and abutment screws.\n        Features a swivel hole for added maneuverability and a hex driver end for direct use.\u003c\/p\u003e\n      \u003cdiv style=\"margin: 0 0 8px; background:#fff; border-radius:8px; padding:12px; border:1px solid var(--c-border);\"\u003e\n        \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/UniversalKit-Component_2.png?v=1785904505\" style=\"display:block;width:100%;max-width:100%;\" alt=\"Universal Prosthetic Kit Driver Holder DH01 — swivel hole and hex driver end\"\u003e\n      \u003c\/div\u003e\n\n      \u003c!-- 3. Torque Ratchet --\u003e\n      \u003ch3 style=\"font-size:1em;font-weight:700;color:var(--c-text);margin-top:32px;margin-bottom:4px;\"\u003e3. Torque Ratchet\n         \u003cspan style=\"font-weight:400;color:#555;font-size:0.9em;\"\u003eTW60\u003c\/span\u003e\n\u003c\/h3\u003e\n      \u003cp class=\"kit-note\" style=\"margin-top:0;margin-bottom:12px;\"\u003eTightens the hex driver and\n        measures torque. By changing the direction of the tip, tightening and loosening can be\n        controlled independently.\u003c\/p\u003e\n      \u003cdiv style=\"margin: 0 0 8px; background:#fff; border-radius:8px; padding:12px; border:1px solid var(--c-border);\"\u003e\n        \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/UniversalKit-Component_3.png?v=1785904506\" style=\"display:block;width:100%;max-width:100%;\" alt=\"Universal Prosthetic Kit Torque Ratchet TW60 — T-bar handle with torque measurement scale and direction selector\"\u003e\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── SPECIFICATIONS ─────────────────────────────────────────── --\u003e\n  \u003cdiv class=\"pd-section\"\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv class=\"pd-label\"\u003eSpecifications\u003c\/div\u003e\n      \u003ch2 class=\"pd-h2\"\u003eTechnical specifications\u003c\/h2\u003e\n\n      \u003ctable class=\"spec-table\"\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eDevice type\u003c\/td\u003e\n          \u003ctd\u003eUniversal prosthetic driver kit for implant abutment and screw tightening\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eMaterial\u003c\/td\u003e\n          \u003ctd\u003eMedical grade titanium and stainless steel\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eDriver types\u003c\/td\u003e\n          \u003ctd\u003e1.2 Hex (0.48\") · 1.25 Hex (0.5\") · SCS · Unigrip\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eDriver lengths\u003c\/td\u003e\n          \u003ctd\u003e10mm (short) · 15mm (long), both supplied per driver type\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eSterility\u003c\/td\u003e\n          \u003ctd\u003eNon-sterile medical device — must be sterilised by autoclave before and after each procedure\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eSterilisation (Pre-Vacuum)\u003c\/td\u003e\n          \u003ctd\u003e132°C · 2 bar · 3 min exposure · 30 min dry\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eSterilisation (Gravity)\u003c\/td\u003e\n          \u003ctd\u003e132°C · 1 bar · 40 min exposure · 30 min dry\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eManufacturer\u003c\/td\u003e\n          \u003ctd\u003eNeobiotech Co., Ltd, Seoul, Korea\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eOrigin\u003c\/td\u003e\n          \u003ctd\u003eMade in Korea\u003c\/td\u003e\n        \u003c\/tr\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── OPERATING TIPS ────────────────────────────────────────── --\u003e\n  \u003cdiv class=\"pd-section\"\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv class=\"pd-label\"\u003eOperating Tips\u003c\/div\u003e\n      \u003ch2 class=\"pd-h2\"\u003eGetting the most from the Universal Prosthetic Kit\u003c\/h2\u003e\n      \u003cp class=\"pd-lead\"\u003ePractical guidance for chairside prosthetic procedures using the\n        Universal Prosthetic Kit.\u003c\/p\u003e\n\n      \u003cdiv class=\"tips-list\"\u003e\n\n        \u003cdiv class=\"tip-item\"\u003e\n          \u003cdiv class=\"tip-num\"\u003e1\u003c\/div\u003e\n          \u003cdiv class=\"tip-body\"\u003e\n\u003cstrong\u003eConfirm driver compatibility before each case.\u003c\/strong\u003e\n            Select the driver type that matches the implant system being restored. Use the\n            compatibility list as a reference if there is any uncertainty. Using an incorrect\n            driver size risks stripping the abutment screw head, which can make screw removal\n            difficult or impossible without specialist intervention.\u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"tip-item\"\u003e\n          \u003cdiv class=\"tip-num\"\u003e2\u003c\/div\u003e\n          \u003cdiv class=\"tip-body\"\u003e\n\u003cstrong\u003eUse the 10mm (short) driver for posterior access.\u003c\/strong\u003e\n            The 15mm long driver provides better torque transmission when used with the Torque\n            Ratchet. In posterior sites with limited vertical access, the 10mm driver reduces\n            the risk of the driver disengaging mid-tightening. For most anterior abutment\n            tightening, the 15mm driver combined with the Driver Holder gives the best control.\u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"tip-item\"\u003e\n          \u003cdiv class=\"tip-num\"\u003e3\u003c\/div\u003e\n          \u003cdiv class=\"tip-body\"\u003e\n\u003cstrong\u003eUse the Driver Holder for all intraoral cover screw and healing abutment\n              work.\u003c\/strong\u003e\n            The Driver Holder connects to any driver in the kit and allows precise intraoral\n            manipulation of cover screws and healing abutments without dropping. The swivel hole\n            allows the angle to be adjusted for difficult access sites, which is particularly\n            useful in second-stage surgery where visibility is limited by soft tissue.\u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"tip-item\"\u003e\n          \u003cdiv class=\"tip-num\"\u003e4\u003c\/div\u003e\n          \u003cdiv class=\"tip-body\"\u003e\n\u003cstrong\u003eApply final torque with the Torque Ratchet — not finger pressure alone.\u003c\/strong\u003e\n            The Torque Ratchet (TW60) allows the direction of tightening and loosening to be\n            selected independently by changing the tip direction. Always use the ratchet for final\n            abutment screw torque. The scale provides a reference for confirming correct torque\n            delivery, reducing the risk of under-tightening (screw loosening in function) or\n            over-tightening (screw fracture).\u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"tip-item\"\u003e\n          \u003cdiv class=\"tip-num\"\u003e5\u003c\/div\u003e\n          \u003cdiv class=\"tip-body\"\u003e\n\u003cstrong\u003eSterilise the full kit before and after each patient procedure.\u003c\/strong\u003e\n            All instruments in the Universal Prosthetic Kit are non-sterile medical devices and\n            must be sterilised by autoclave before use and after each procedure. Recommended\n            autoclave conditions: Pre-Vacuum 132°C \/ 2 bar \/ 3 min exposure \/ 30 min dry, or\n            Gravity 132°C \/ 1 bar \/ 40 min exposure \/ 30 min dry. After use, detach each\n            component, wash promptly, dry thoroughly, and store at room temperature away from\n            soiled areas before re-sterilising.\u003c\/div\u003e\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"tip-warn\"\u003e\n        \u003cstrong\u003e⚠ Clinical Notice:\u003c\/strong\u003e The Universal Prosthetic Kit is a non-sterile medical\n        device intended for use by trained dental surgeons and prosthodontists. The kit must be\n        sterilised by autoclave before and after each patient procedure. Use only with compatible\n        implant systems as listed in the product compatibility guide. Follow AS\/NZS sterilisation\n        and infection control guidelines. Refer to the product Instructions for Use for full\n        indications, contraindications, and handling instructions.\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e","brand":"Neobiotech","offers":[{"title":"Default Title","offer_id":49138038407458,"sku":"UVPRTKITV","price":2300.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/uiversalprosthetickit.png?v=1732110954"},{"product_id":"anthogyr-torq-control","title":"Anthogyr Torq Control","description":"  \u003cdiv\u003e\n    \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/Hero-Anthogyr_TorqueControl.png?v=1782193145\" style=\"display:block;max-width:100%;justify-self:center;\" alt=\"Anthogyr Torq Control Universal Torque Wrench\"\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── HERO ──────────────────────────────────────────────────── --\u003e\n  \u003cdiv class=\"pd-hero\"\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv class=\"pd-hero-tag\"\u003eAnthogyr · Implant Prosthetics\u003c\/div\u003e\n      \u003ch1 class=\"pd-hero-title\"\u003eTorq Control®\u003cbr\u003eUniversal Torque Wrench\u003c\/h1\u003e\n      \u003cp class=\"pd-hero-sub\"\u003e\n        Torq Control® is the Anthogyr universal torque wrench ensuring precise tightening — crucial for implant\n        success, regardless of connection type or access constraints. Designed for all prosthetic procedures, it\n        offers optimal safety with automatic declutching when the selected torque is reached. A must-have,\n        especially for full arch restorations.\n      \u003c\/p\u003e\n      \u003cdiv class=\"pd-hero-badges\"\u003e\n        \u003cspan class=\"pd-hero-badge\"\u003e\n          \u003csvg viewbox=\"0 0 16 16\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.8\"\u003e\n            \u003ccircle cx=\"8\" cy=\"8\" r=\"6.5\"\u003e\u003c\/circle\u003e\n            \u003cpath d=\"M5 8.5l2 2 4-4\"\u003e\u003c\/path\u003e\n          \u003c\/svg\u003e\n          Universal — Any Implant System\n        \u003c\/span\u003e\n        \u003cspan class=\"pd-hero-badge\"\u003e\n          \u003csvg viewbox=\"0 0 16 16\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.8\"\u003e\n            \u003cpath d=\"M3 12l4-4 3 3 4-5\"\u003e\u003c\/path\u003e\n          \u003c\/svg\u003e\n          Automatic Declutching at Target Torque\n        \u003c\/span\u003e\n        \u003cspan class=\"pd-hero-badge\"\u003e\n          \u003csvg viewbox=\"0 0 16 16\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.8\"\u003e\n            \u003cpath d=\"M8 2v12M2 8h12\"\u003e\u003c\/path\u003e\n          \u003c\/svg\u003e\n          Made in France — Trusted Since 1997\n        \u003c\/span\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── CLINICAL INSIGHT ──────────────────────────────────────── --\u003e\n  \u003cdiv class=\"pd-section\"\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv class=\"pd-label\"\u003eClinical Insight\u003c\/div\u003e\n      \u003ch2 class=\"pd-h2\"\u003eWhat clinicians are saying\u003c\/h2\u003e\n      \u003cp class=\"pd-lead\"\u003eReal-world feedback from implantologists and prosthodontists using Torq Control® in their\n        practices.\u003c\/p\u003e\n\n      \u003cdiv class=\"insights-grid\"\u003e\n        \u003cdiv class=\"insight-card\"\u003e\n          \u003cp class=\"insight-quote\"\u003e\n            \"The 100° micro-head is the feature that sold me — I work heavily in posterior sectors and visibility\n            has always been a limiting factor with conventional wrenches. With Torq Control® I can confirm seating\n            and complete tightening in a single, confident movement. The automatic declutching gives me certainty\n            that I haven't over-torqued, which matters enormously in the abutment screw longevity conversation.\"\n          \u003c\/p\u003e\n          \u003cdiv class=\"insight-tag\"\u003ePosterior Access · Abutment Screw · Torque Accuracy\u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"insight-card\"\u003e\n          \u003cp class=\"insight-quote\"\u003e\n            \"For full arch cases, I'm torquing anywhere from four to six screws in a single appointment.\n            Torq Control® makes that repeatable — same 130g instrument, same feel, same declutch every time.\n            The dial is easy to read and adjust chairside, and the autoclavability means it goes straight\n            from the cassette to the patient. It's an instrument I stopped thinking about, which is exactly\n            what a good tool should be.\"\n          \u003c\/p\u003e\n          \u003cdiv class=\"insight-tag\"\u003eFull Arch · Repeatability · Workflow\u003c\/div\u003e\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── RESOURCES ─────────────────────────────────────────────── --\u003e\n  \u003cdiv class=\"pd-section pd-section--muted\"\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv class=\"pd-label\"\u003eResources\u003c\/div\u003e\n      \u003ch2 class=\"pd-h2\"\u003eProduct Documentation\u003c\/h2\u003e\n      \u003cdiv class=\"dl-grid\"\u003e\n        \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/Anthogyr_Torque_Control_Brochure-X_Dental.pdf?v=1765074686\" class=\"dl-btn\" target=\"_blank\"\u003e\n          \u003csvg viewbox=\"0 0 16 16\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.8\"\u003e\n            \u003cpath d=\"M3 13h10M8 2v8M5 7l3 3 3-3\"\u003e\u003c\/path\u003e\n          \u003c\/svg\u003e\n          Product Brochure\n        \u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── FEATURE HIGHLIGHTS ────────────────────────────────────── --\u003e\n  \u003cdiv class=\"pd-section\"\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv class=\"pd-label\"\u003eHighlights\u003c\/div\u003e\n      \u003ch2 class=\"pd-h2\"\u003eDesigned for precision, built for everyday use\u003c\/h2\u003e\n      \u003cp class=\"pd-lead\"\u003eEvery detail of Torq Control® is engineered to deliver consistent, safe prosthetic\n        tightening — with no compromises on access, control, or maintenance.\u003c\/p\u003e\n\n      \u003cdiv class=\"feature-block\"\u003e\n        \u003cdiv class=\"feature-media\"\u003e\n          \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/Anthogyr_Features_1.png?v=1782195951\" alt=\"Torq Control 100-degree micro-head for posterior access\"\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"feature-copy\"\u003e\n          \u003cp class=\"feature-tag\"\u003eAccess\u003c\/p\u003e\n          \u003ch3 class=\"feature-headline\"\u003e100° micro-head for posterior access\u003c\/h3\u003e\n          \u003cdiv class=\"pillar-desc\"\u003e\n            \u003cp\u003eThe micro-head is angulated at 100° to maintain easy access and optimal visibility even in the\n              most confined posterior sectors — without repositioning the patient or compromising the tightening\n              angle.\u003c\/p\u003e\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"feature-block reverse\"\u003e\n        \u003cdiv class=\"feature-media\"\u003e\n          \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/Anthogyr_Features_2.png?v=1782195951\" alt=\"Torq Control torque dial showing 7 settings from 10 to 35 N.cm\"\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"feature-copy\"\u003e\n          \u003cp class=\"feature-tag\"\u003ePrecision\u003c\/p\u003e\n          \u003ch3 class=\"feature-headline\"\u003e7 torque values, automatic declutching\u003c\/h3\u003e\n          \u003cdiv class=\"pillar-desc\"\u003e\n            \u003cp\u003eSeven selectable torque settings from 10 to 35 N.cm cover the full range of implant prosthetic\n              protocols. The wrench automatically declutches the moment the target torque is reached —\n              preventing over-tightening with no reliance on operator feel.\u003c\/p\u003e\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"feature-block\"\u003e\n        \u003cdiv class=\"feature-media\"\u003e\n          \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/Anthogyr_Features_3.png?v=1782195951\" alt=\"Torq Control held in clinical use — manipulation fully outside the mouth\"\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"feature-copy\"\u003e\n          \u003cp class=\"feature-tag\"\u003eComfort\u003c\/p\u003e\n          \u003ch3 class=\"feature-headline\"\u003e130 g — manipulation fully outside the mouth\u003c\/h3\u003e\n          \u003cdiv class=\"pillar-desc\"\u003e\n            \u003cp\u003eAt only 130 g, Torq Control® allows complete freedom of movement. Torque is applied entirely\n              outside the mouth with no lateral movement — maximising patient comfort and giving the operator\n              full tactile control throughout the procedure.\u003c\/p\u003e\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── ANNOTATED DIAGRAM ─────────────────────────────────────── --\u003e\n  \u003cdiv class=\"pd-section pd-section--muted\"\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv class=\"pd-label\"\u003eProduct Overview\u003c\/div\u003e\n      \u003ch2 class=\"pd-h2\"\u003eUniversal torque wrench\u003c\/h2\u003e\n      \u003cp class=\"pd-lead\"\u003eSix design features working together — from the 100° micro-head to automatic declutching\n        at the base.\u003c\/p\u003e\n      \u003cdiv style=\"margin:28px 0;border-radius:12px;overflow:hidden;line-height:0;\"\u003e\n        \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/Anthogyr_TorqueControl-img_1.png?v=1782197275\" style=\"display:block;width:100%;max-width:100%;\" alt=\"Torq Control annotated diagram — 100 degree micro-head, universal connection, ergonomic design, manual instrument, 7 torque values, automatic declutching\"\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── THREE PILLARS ─────────────────────────────────────────── --\u003e\n  \u003cdiv class=\"pd-section\"\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv class=\"pd-label\"\u003eWhy Torq Control®\u003c\/div\u003e\n      \u003ch2 class=\"pd-h2\"\u003ePerformance, ergonomics, and reliability in one instrument\u003c\/h2\u003e\n      \u003cp class=\"pd-lead\"\u003eThree pillars that have made Torq Control® an icon of implant prosthetics since 1997.\u003c\/p\u003e\n\n      \u003cdiv class=\"pillar-grid\"\u003e\n\n        \u003cdiv class=\"pillar-card\"\u003e\n          \u003cdiv class=\"pillar-icon\"\u003e\n            \u003csvg viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.8\"\u003e\n              \u003ccircle cx=\"12\" cy=\"12\" r=\"9\"\u003e\u003c\/circle\u003e\n              \u003cpath d=\"M12 7v5l3 3\"\u003e\u003c\/path\u003e\n            \u003c\/svg\u003e\n          \u003c\/div\u003e\n          \u003cdiv class=\"pillar-title\"\u003eHigh Performance\u003c\/div\u003e\n          \u003cdiv class=\"pillar-desc\"\u003e\n            \u003cp\u003eHigh precision torque tightening with automatic declutching at the selected value. Universal\n              connection accepts all prosthetic mandrels across any implant system.\u003c\/p\u003e\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"pillar-card\"\u003e\n          \u003cdiv class=\"pillar-icon\"\u003e\n            \u003csvg viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.8\"\u003e\n              \u003cpath d=\"M12 3c-4 2.5-7 6.5-7 9a7 7 0 0014 0c0-2.5-3-6.5-7-9z\"\u003e\u003c\/path\u003e\n              \u003cpath d=\"M9 13l2 2 4-4\"\u003e\u003c\/path\u003e\n            \u003c\/svg\u003e\n          \u003c\/div\u003e\n          \u003cdiv class=\"pillar-title\"\u003eErgonomics \u0026amp; Ease of Use\u003c\/div\u003e\n          \u003cdiv class=\"pillar-desc\"\u003e\n            \u003cp\u003eAt just 130 g, the instrument offers maximum freedom of movement. The manual screw-in feel gives\n              operators full tactile control, with all manipulation performed outside the mouth.\u003c\/p\u003e\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"pillar-card\"\u003e\n          \u003cdiv class=\"pillar-icon\"\u003e\n            \u003csvg viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.8\"\u003e\n              \u003cpath d=\"M12 2l2.4 7.4H22l-6.2 4.5 2.4 7.4L12 17l-6.2 4.3 2.4-7.4L2 9.4h7.6z\"\u003e\u003c\/path\u003e\n            \u003c\/svg\u003e\n          \u003c\/div\u003e\n          \u003cdiv class=\"pillar-title\"\u003eReliability \u0026amp; Quality\u003c\/div\u003e\n          \u003cdiv class=\"pillar-desc\"\u003e\n            \u003cp\u003eOne-piece design, autoclavable at 135°, and repairable. Made in the Mont-Blanc Valley, France,\n              since 1997 — trusted by professionals for over 25 years.\u003c\/p\u003e\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"pd-section pd-section--muted\"\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv style=\"margin:28px 0;border-radius:12px;overflow:hidden;background:#f0f0f0;line-height:0;\"\u003e\n        \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/Anthogyr_TorqueControl-img_2.png?v=1782197280\" style=\"display:block;width:100%;max-width:100%;\" alt=\"Torq Control comprehensive design views\"\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── SPECIFICATIONS ─────────────────────────────────────────── --\u003e\n  \u003cdiv class=\"pd-section\"\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv class=\"pd-label\"\u003eSpecifications\u003c\/div\u003e\n      \u003ch2 class=\"pd-h2\"\u003eTechnical specifications\u003c\/h2\u003e\n\n      \u003ctable class=\"spec-table\"\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eDevice type\u003c\/td\u003e\n          \u003ctd\u003eUniversal manual torque wrench\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eConnection\u003c\/td\u003e\n          \u003ctd\u003eUniversal — compatible with all prosthetic mandrels and implant systems\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eTorque range\u003c\/td\u003e\n          \u003ctd\u003e10 · 15 · 20 · 25 · 30 · 32 · 35 N.cm (7 selectable values)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eHead angle\u003c\/td\u003e\n          \u003ctd\u003e100°\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eDeclutching\u003c\/td\u003e\n          \u003ctd\u003eAutomatic — releases when the selected torque value is reached\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eWeight\u003c\/td\u003e\n          \u003ctd\u003e130 g\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eSterilisation\u003c\/td\u003e\n          \u003ctd\u003eAutoclavable at 135°\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eDesign\u003c\/td\u003e\n          \u003ctd\u003eOne-piece — repairable\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eManufacturer\u003c\/td\u003e\n          \u003ctd\u003eAnthogyr — A Straumann Group Brand\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eOrigin\u003c\/td\u003e\n          \u003ctd\u003eMade in France (Mont-Blanc Valley) — since 1997\u003c\/td\u003e\n        \u003c\/tr\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── OPERATING TIPS ────────────────────────────────────────── --\u003e\n  \u003cdiv class=\"pd-section\"\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv class=\"pd-label\"\u003eOperating Tips\u003c\/div\u003e\n      \u003ch2 class=\"pd-h2\"\u003eGetting the most from your Torq Control®\u003c\/h2\u003e\n      \u003cp class=\"pd-lead\"\u003ePractical guidance for accurate, consistent torque delivery in daily prosthetic use.\u003c\/p\u003e\n\n      \u003cdiv class=\"tips-list\"\u003e\n        \u003cdiv class=\"tip-item\"\u003e\n          \u003cdiv class=\"tip-num\"\u003e1\u003c\/div\u003e\n          \u003cdiv class=\"tip-body\"\u003e\n\u003cstrong\u003eSet the torque value before connecting to the abutment screw.\u003c\/strong\u003e\n            Rotate the dial at the base to the required torque setting before engaging the mandrel. Confirm\n            the selected value against the implant manufacturer's abutment screw protocol — torque requirements\n            vary by screw size, material, and connection type. Do not adjust the dial mid-tightening.\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"tip-item\"\u003e\n          \u003cdiv class=\"tip-num\"\u003e2\u003c\/div\u003e\n          \u003cdiv class=\"tip-body\"\u003e\n\u003cstrong\u003eLet the automatic declutching do its job — do not force past the click.\u003c\/strong\u003e\n            Torq Control® is designed to release the drive mechanism the moment the target torque is reached.\n            Applying additional force after declutching will not increase the delivered torque — it bypasses\n            the safety mechanism and risks screw deformation or overload on the implant-abutment interface.\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"tip-item\"\u003e\n          \u003cdiv class=\"tip-num\"\u003e3\u003c\/div\u003e\n          \u003cdiv class=\"tip-body\"\u003e\n\u003cstrong\u003eUse the 100° head angle to your advantage in posterior sectors.\u003c\/strong\u003e\n            Position the wrench so the body sits at the angulation that gives the clearest sightline to the\n            screw head — the 100° offset is specifically designed to maintain drive axis alignment while keeping\n            the handle outside the mouth. Avoid tilting the handle laterally to compensate for access; reposition\n            the patient or retraction instead.\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"tip-item\"\u003e\n          \u003cdiv class=\"tip-num\"\u003e4\u003c\/div\u003e\n          \u003cdiv class=\"tip-body\"\u003e\n\u003cstrong\u003eSterilise after every use — the one-piece design makes this\n              straightforward.\u003c\/strong\u003e\n            Torq Control® is autoclavable at 135° and its one-piece construction means no disassembly is required. To\n            maintain TGA compliance and measurement accuracy, annual calibration is highly recommended. Inspect the\n            mechanism before each use; if the declutching feels inconsistent, contact X DENTAL immediately for official\n            repair and technical support rather than continuing clinical use.\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"tip-item\"\u003e\n          \u003cdiv class=\"tip-num\"\u003e5\u003c\/div\u003e\n          \u003cdiv class=\"tip-body\"\u003e\n\u003cstrong\u003eFor full arch cases, confirm each screw individually before moving to the\n              next.\u003c\/strong\u003e The declutch confirmation at each position is your audit trail that every screw\n            has received the prescribed torque. In full arch restorations where multiple abutment screws are\n            placed, work in a consistent sequence and record each position — particularly when a mixture of\n            screw sizes or torque values are used across the arch.\u003c\/div\u003e\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"tip-warn\"\u003e\n        \u003cstrong\u003e⚠ Operating Notice:\u003c\/strong\u003e Torq Control® is intended for use by trained dental professionals\n        in implant prosthetic procedures. Always verify the required torque value against the implant system\n        manufacturer's instructions before use. Do not exceed the maximum torque setting. Follow AS\/NZS\n        sterilisation guidelines for autoclave protocols. Refer to the Instructions for Use for full operating,\n        maintenance, and safety information.\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e","brand":"Anthogyr","offers":[{"title":"Default Title","offer_id":49138127143202,"sku":"Anthogyr","price":1575.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/TORQ-Control.jpg?v=1732780198"}],"url":"https:\/\/xdentalsupplies.com.au\/collections\/torque-prosthetic-kits.oembed","provider":"X Dental Supplies","version":"1.0","type":"link"}