{"product_id":"coxo-electric-torque-wrench","title":"COXO Electric Torque Wrench","description":"  \u003cdiv\u003e\n    \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/COXO_Torque_Wrench.png?v=1793601362\" style=\"display:block;max-width:100%;justify-self:center;\" alt=\"COXO C-TW3 electric dental implant torque wrench with screwdriver\"\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── HERO ──────────────────────────────────────────────────── --\u003e\n  \u003cdiv class=\"pd-hero\"\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv class=\"pd-hero-tag\"\u003eCOXO · Implant Torque Control\u003c\/div\u003e\n      \u003ch1 class=\"pd-hero-title\"\u003eC-TW3\u003cbr\u003eElectric Torque Wrench\u003c\/h1\u003e\n      \u003cp class=\"pd-hero-sub\"\u003e\n        The C-TW3 is a compact, cordless electric torque wrench for implant dentistry — delivering precise, controlled\n        torque from 10 to 55 N·cm at low speed. Rechargeable and free of a trailing cord, it pairs a simple multi-button\n        layout for one-touch control of torque, speed and direction with an intelligent deceleration mode that eases off\n        automatically as the target torque approaches — for confident final seating at just 100 g in the hand.\n      \u003c\/p\u003e\n      \u003cdiv class=\"pd-hero-badges\"\u003e\n        \u003cspan class=\"pd-hero-badge\"\u003e\n          \u003csvg viewbox=\"0 0 16 16\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.8\"\u003e\n            \u003ccircle cx=\"8\" cy=\"8\" r=\"6.5\"\u003e\u003c\/circle\u003e\n            \u003cpath d=\"M5 8.5l2 2 4-4\"\u003e\u003c\/path\u003e\n          \u003c\/svg\u003e\n          10–55 N·cm · ±3 N·cm Accuracy\n        \u003c\/span\u003e\n        \u003cspan class=\"pd-hero-badge\"\u003e\n          \u003csvg viewbox=\"0 0 16 16\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.8\"\u003e\n            \u003cpath d=\"M3 12l4-4 3 3 4-5\"\u003e\u003c\/path\u003e\n          \u003c\/svg\u003e\n          Low Speed · 5–50 r\/min\n        \u003c\/span\u003e\n        \u003cspan class=\"pd-hero-badge\"\u003e\n          \u003csvg viewbox=\"0 0 16 16\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.8\"\u003e\n            \u003cpath d=\"M8 2v12M2 8h12\"\u003e\u003c\/path\u003e\n          \u003c\/svg\u003e\n          Cordless \u0026amp; Rechargeable · ~100 g\n        \u003c\/span\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── CLINICAL INSIGHT ──────────────────────────────────────── --\u003e\n  \u003cdiv class=\"pd-section\"\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv class=\"pd-label\"\u003eClinical Insight\u003c\/div\u003e\n      \u003ch2 class=\"pd-h2\"\u003eWhat clinicians are saying\u003c\/h2\u003e\n      \u003cp class=\"pd-lead\"\u003eReal-world feedback from implant clinicians using the C-TW3 for seating and torque\n        verification.\u003c\/p\u003e\n\n      \u003cdiv class=\"insights-grid\"\u003e\n        \u003cdiv class=\"insight-card\"\u003e\n          \u003cp class=\"insight-quote\"\u003e\n            \"For final seating I want to feel in control of the last few N·cm, not just hear a click. The deceleration\n            mode slows the driver right down as it nears the set value, so I'm placing the abutment smoothly instead of\n            over-running the torque. Reading the exact figure off the device takes the guesswork out of it for me.\"\n          \u003c\/p\u003e\n          \u003cdiv class=\"insight-tag\"\u003eAbutment Seating · Torque Control\u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"insight-card\"\u003e\n          \u003cp class=\"insight-quote\"\u003e\n            \"It's light enough that my hand doesn't tire on a longer list, and small enough to get a straight line into\n            the posterior. Switching torque, speed and direction from the buttons keeps my attention on the patient\n            rather than on setting up the instrument. For routine placements it's become the one I reach for.\"\n          \u003c\/p\u003e\n          \u003cdiv class=\"insight-tag\"\u003ePosterior Access · Handling · Everyday Use\u003c\/div\u003e\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── RESOURCES ─────────────────────────────────────────────── --\u003e\n  \u003cdiv class=\"pd-section\"\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv class=\"pd-label\"\u003eResources\u003c\/div\u003e\n      \u003ch2 class=\"pd-h2\"\u003eProduct Documentation\u003c\/h2\u003e\n      \u003c!-- Set each href to the uploaded PDF (Shopify CDN URL): Product Brochure + User Manual. --\u003e\n      \u003cdiv class=\"dl-grid\"\u003e\n        \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/COXO-C-TW3-Brochure_X-DENTAL.pdf?v=1793603499\" class=\"dl-btn\" target=\"_blank\"\u003e\n          \u003csvg viewbox=\"0 0 16 16\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.8\"\u003e\n            \u003cpath d=\"M3 13h10M8 2v8M5 7l3 3 3-3\"\u003e\u003c\/path\u003e\n          \u003c\/svg\u003e\n          Product Brochure\n        \u003c\/a\u003e\n        \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/COXO-C-TW3-User-Manual_X-DENTAL.pdf?v=1793605222\" class=\"dl-btn\" target=\"_blank\"\u003e\n          \u003csvg viewbox=\"0 0 16 16\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.8\"\u003e\n            \u003cpath d=\"M3 13h10M8 2v8M5 7l3 3 3-3\"\u003e\u003c\/path\u003e\n          \u003c\/svg\u003e\n          User Manual\n        \u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── THREE PILLARS ─────────────────────────────────────────── --\u003e\n  \u003cdiv class=\"pd-section pd-section--muted\"\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv class=\"pd-label\"\u003eWhy C-TW3\u003c\/div\u003e\n      \u003ch2 class=\"pd-h2\"\u003ePrecise torque, in a tool that disappears in the hand\u003c\/h2\u003e\n      \u003cp class=\"pd-lead\"\u003eThree things an implant clinician wants from a powered torque driver — an accurate number, a\n        controlled finish, and a body light enough to forget about.\u003c\/p\u003e\n\n      \u003cdiv class=\"pillar-grid\"\u003e\n        \u003cdiv class=\"pillar-card\"\u003e\n          \u003cdiv class=\"pillar-icon\"\u003e\n            \u003csvg viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.8\"\u003e\n              \u003ccircle cx=\"12\" cy=\"12\" r=\"9\"\u003e\u003c\/circle\u003e\n              \u003cpath d=\"M12 12l5-3M12 7v5\"\u003e\u003c\/path\u003e\n            \u003c\/svg\u003e\n          \u003c\/div\u003e\n          \u003cdiv class=\"pillar-title\"\u003eAccurate Torque\u003c\/div\u003e\n          \u003cdiv class=\"pillar-desc\"\u003e\n            \u003cp\u003eA 10–55 N·cm range in 5 N·cm steps, held to ±3 N·cm — set the value for the system in front of you and\n              let the device control the finish.\u003c\/p\u003e\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"pillar-card\"\u003e\n          \u003cdiv class=\"pillar-icon\"\u003e\n            \u003csvg viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.8\"\u003e\n              \u003cpath d=\"M4 12a8 8 0 018-8 8 8 0 018 8\"\u003e\u003c\/path\u003e\n              \u003cpath d=\"M12 12l4 2\"\u003e\u003c\/path\u003e\n              \u003cpath d=\"M4 12l2.5 2.5M20 12l-2.5 2.5\"\u003e\u003c\/path\u003e\n            \u003c\/svg\u003e\n          \u003c\/div\u003e\n          \u003cdiv class=\"pillar-title\"\u003eControlled Finish\u003c\/div\u003e\n          \u003cdiv class=\"pillar-desc\"\u003e\n            \u003cp\u003eIntelligent deceleration eases the driver down as it nears the target, so final seating is smooth and\n              controlled rather than an abrupt stop.\u003c\/p\u003e\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"pillar-card\"\u003e\n          \u003cdiv class=\"pillar-icon\"\u003e\n            \u003csvg viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.8\"\u003e\n              \u003cpath d=\"M7 3h10v4l-5 5-5-5z\"\u003e\u003c\/path\u003e\n              \u003cpath d=\"M12 12v9\"\u003e\u003c\/path\u003e\n            \u003c\/svg\u003e\n          \u003c\/div\u003e\n          \u003cdiv class=\"pillar-title\"\u003eCompact \u0026amp; Light\u003c\/div\u003e\n          \u003cdiv class=\"pillar-desc\"\u003e\n            \u003cp\u003eAbout 100 g and roughly 17 mm across — a slim, balanced body that reduces hand fatigue and reaches\n              straight into the posterior.\u003c\/p\u003e\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── FEATURE HIGHLIGHTS (2-col cards: image top + text bottom) ── --\u003e\n  \u003cdiv class=\"pd-section\"\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv class=\"pd-label\"\u003eHighlights\u003c\/div\u003e\n      \u003ch2 class=\"pd-h2\"\u003eDesigned around the final few newton-centimetres\u003c\/h2\u003e\n      \u003cp class=\"pd-lead\"\u003eEvery detail of the C-TW3 is built to make controlled, repeatable torque delivery simple at the\n        chairside.\u003c\/p\u003e\n\n      \u003cdiv class=\"feature-cards\"\u003e\n\n        \u003cdiv class=\"feature-card\"\u003e\n          \u003cdiv class=\"feature-media\"\u003e\n            \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/COXO_Torque_Wrench_Features_1.png?v=1793602482\" alt=\"C-TW3 showing the set torque value on its readout\"\u003e\n          \u003c\/div\u003e\n          \u003cdiv class=\"feature-copy\"\u003e\n            \u003cp class=\"feature-tag\"\u003ePrecision\u003c\/p\u003e\n            \u003ch3 class=\"feature-headline\"\u003eSet the number, hold the number\u003c\/h3\u003e\n            \u003cdiv class=\"pillar-desc\"\u003e\n              \u003cp\u003eTorque is set across 10–55 N·cm in 5 N·cm increments and held to ±3 N·cm, so the value you choose for\n                the implant system is the value delivered — read directly from the device rather than estimated by\n                feel.\u003c\/p\u003e\n            \u003c\/div\u003e\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"feature-card\"\u003e\n          \u003cdiv class=\"feature-media\"\u003e\n            \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/COXO_Torque_Wrench_Features_2.png?v=1793601362\" alt=\"C-TW3 multi-button control layout for torque, speed and direction\"\u003e\n          \u003c\/div\u003e\n          \u003cdiv class=\"feature-copy\"\u003e\n            \u003cp class=\"feature-tag\"\u003eControl\u003c\/p\u003e\n            \u003ch3 class=\"feature-headline\"\u003eOne-touch torque, speed \u0026amp; direction\u003c\/h3\u003e\n            \u003cdiv class=\"pillar-desc\"\u003e\n              \u003cp\u003eA simple multi-button layout gives direct access to the four core functions — torque, speed, direction\n                and calibration — with forward\/reverse at your fingertips, keeping attention on the patient, not on the\n                instrument.\u003c\/p\u003e\n            \u003c\/div\u003e\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"feature-card\"\u003e\n          \u003cdiv class=\"feature-media\"\u003e\n            \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/COXO_Torque_Wrench_Features_3.png?v=1793601362\" alt=\"C-TW3 rotatable handpiece head improving intraoral access\"\u003e\n          \u003c\/div\u003e\n          \u003cdiv class=\"feature-copy\"\u003e\n            \u003cp class=\"feature-tag\"\u003eAccess\u003c\/p\u003e\n            \u003ch3 class=\"feature-headline\"\u003eRotatable head for every position\u003c\/h3\u003e\n            \u003cdiv class=\"pillar-desc\"\u003e\n              \u003cp\u003eThe handpiece head rotates to improve the line of approach to different intraoral positions — helping\n                deliver straight, controlled torque even in the posterior, where access is tightest.\u003c\/p\u003e\n            \u003c\/div\u003e\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"feature-card\"\u003e\n          \u003cdiv class=\"feature-media\"\u003e\n            \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/COXO_Torque_Wrench_Features_4.png?v=1793601362\" alt=\"C-TW3 compact ergonomic body held in one hand\"\u003e\n          \u003c\/div\u003e\n          \u003cdiv class=\"feature-copy\"\u003e\n            \u003cp class=\"feature-tag\"\u003eCordless \u0026amp; Ergonomic\u003c\/p\u003e\n            \u003ch3 class=\"feature-headline\"\u003eLight in the hand, free of a cord\u003c\/h3\u003e\n            \u003cdiv class=\"pillar-desc\"\u003e\n              \u003cp\u003eA cordless, rechargeable handpiece at about 100 g and a maximum grip diameter near 17 mm — the balanced\n                body moves freely at the chairside without a trailing cord, reducing operator fatigue across a full\n                implant list. Recharged between cases via the AC adapter.\u003c\/p\u003e\n            \u003c\/div\u003e\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── OPERATING MODES ───────────────────────────────────────── --\u003e\n  \u003cdiv class=\"pd-section pd-section--muted\"\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv class=\"pd-label\"\u003eOperating Modes\u003c\/div\u003e\n      \u003ch2 class=\"pd-h2\"\u003eTwo ways to reach the target\u003c\/h2\u003e\n      \u003cp class=\"pd-lead\"\u003eChoose a constant-speed finish or an automatic deceleration as the target torque approaches.\n      \u003c\/p\u003e\n\n      \u003cdiv class=\"pillar-grid pillar-grid--2\"\u003e\n        \u003cdiv class=\"pillar-card\"\u003e\n          \u003cdiv class=\"feature-media\" style=\"margin-bottom:20px;\"\u003e\n            \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/COXO_Torque_Wrench_Mode_-_Standard.png?v=1793602621\"\u003e\n          \u003c\/div\u003e\n          \u003cdiv class=\"pillar-title\" style=\"text-align: start;\"\u003eStandard Mode\u003c\/div\u003e\n          \u003cdiv class=\"pillar-desc\" style=\"text-align: start;\"\u003e\n            \u003cp\u003eConstant speed control — the driver runs at the set speed and stops immediately once the target torque is\n              reached.\u003c\/p\u003e\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"pillar-card\"\u003e\n          \u003cdiv class=\"feature-media\" style=\"margin-bottom:20px;\"\u003e\n            \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/COXO_Torque_Wrench_Mode_-_Intelligent.png?v=1793602621\"\u003e\n          \u003c\/div\u003e\n          \u003cdiv class=\"pillar-title\" style=\"text-align: start;\"\u003eIntelligent Deceleration Mode\u003c\/div\u003e\n          \u003cdiv class=\"pillar-desc\" style=\"text-align: start;\"\u003e\n            \u003cp\u003eAbove a set speed of 20 r\/min, the driver slows automatically — reducing by 10 r\/min (with a beep) as\n              torque reaches 60% of the set value, and again at 90% — then returns to speed as the load eases, for a\n              smooth, controlled final seating.\u003c\/p\u003e\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n\n      \u003cp class=\"kit-note\" style=\"margin-top:20px;\"\u003e\n        After activation, the C-TW3 runs a 15-second automatic calibration countdown before use.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── APPLICATIONS ──────────────────────────────────────────── --\u003e\n  \u003cdiv class=\"pd-section\"\u003e\n\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv class=\"pd-label\"\u003eApplications\u003c\/div\u003e\n      \u003ch2 class=\"pd-h2\"\u003eLow speed, high torque — where it's needed\u003c\/h2\u003e\n      \u003cp class=\"pd-lead\"\u003eA powered torque driver for the controlled, low-speed stages of implant and related\n        procedures.\u003c\/p\u003e\n\n      \u003cdiv class=\"use-grid use-grid--3\"\u003e\n        \u003cdiv class=\"use-item\"\u003e\n          \u003cdiv class=\"use-icon\"\u003e\n            \u003csvg viewbox=\"0 0 20 20\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.6\"\u003e\n              \u003cpath d=\"M10 3v9M7 6l3-3 3 3\"\u003e\u003c\/path\u003e\n              \u003crect x=\"6\" y=\"12\" width=\"8\" height=\"5\" rx=\"1\"\u003e\u003c\/rect\u003e\n            \u003c\/svg\u003e\n          \u003c\/div\u003e\n          \u003cdiv class=\"use-text\"\u003e\n\u003cstrong\u003eImplant Placement\u003c\/strong\u003e\n            \u003cbr\u003eControlled, low-speed insertion of the implant\n            fixture to the target torque.\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"use-item\"\u003e\n          \u003cdiv class=\"use-icon\"\u003e\n            \u003csvg viewbox=\"0 0 20 20\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.6\"\u003e\n              \u003cpath d=\"M10 2l2 4h-4z\"\u003e\u003c\/path\u003e\n              \u003crect x=\"8\" y=\"6\" width=\"4\" height=\"8\" rx=\"1\"\u003e\u003c\/rect\u003e\n              \u003cpath d=\"M7 17h6\"\u003e\u003c\/path\u003e\n            \u003c\/svg\u003e\n          \u003c\/div\u003e\n          \u003cdiv class=\"use-text\"\u003e\n\u003cstrong\u003eAbutment Placement\u003c\/strong\u003e\n            \u003cbr\u003eSeating and final torque of abutments to\n            manufacturer-specified values.\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"use-item\"\u003e\n          \u003cdiv class=\"use-icon\"\u003e\n            \u003csvg viewbox=\"0 0 20 20\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.6\"\u003e\n              \u003ccircle cx=\"10\" cy=\"6\" r=\"2.5\"\u003e\u003c\/circle\u003e\n              \u003cpath d=\"M10 8.5V17M7 14l3 3 3-3\"\u003e\u003c\/path\u003e\n            \u003c\/svg\u003e\n          \u003c\/div\u003e\n          \u003cdiv class=\"use-text\"\u003e\n\u003cstrong\u003eOrthodontic Mini-Screws\u003c\/strong\u003e\n            \u003cbr\u003ePrecise placement of orthodontic\n            mini-screws at controlled torque.\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- ── PRODUCT IMAGE — FULL WIDTH ────────────────────────────── --\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv style=\"overflow:hidden;line-height:0;\"\u003e\n        \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/COXO_Torque_Wrench_C-TW3.png?v=1793601455\" style=\"display:block;width:80%;max-width:80%;margin-top:50px;border-radius:12px;margin-left:auto;margin-right:auto;\" alt=\"COXO C-TW3 Dental Electric Torque Wrench\"\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── COMPATIBILITY ─────────────────────────────────────────── --\u003e\n  \u003cdiv class=\"pd-section pd-section--muted\"\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv class=\"pd-label\"\u003eCompatibility\u003c\/div\u003e\n      \u003ch2 class=\"pd-h2\"\u003e16 screwdrivers · 8 implant interface types\u003c\/h2\u003e\n      \u003cp class=\"pd-lead\"\u003eThe standard set includes 16 screwdrivers covering the 8 common implant interface types below —\n        so the C-TW3 works across a wide range of mainstream implant systems.\u003c\/p\u003e\n\n      \u003cdiv class=\"feature-media\" style=\"aspect-ratio:auto;margin-top:24px;\"\u003e\n        \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/C-TW3_Screwdrivers.png?v=1793601898\" alt=\"COXO C-TW3 standard screwdriver set covering 16 implant interface specifications in a holder\"\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"kit-table-wrap\"\u003e\n        \u003ctable class=\"kit-table\"\u003e\n          \u003cthead\u003e\n            \u003ctr\u003e\n              \u003cth\u003eCode\u003c\/th\u003e\n              \u003cth\u003eImplant System\u003c\/th\u003e\n              \u003cth\u003eCompatible Systems\u003c\/th\u003e\n            \u003c\/tr\u003e\n          \u003c\/thead\u003e\n          \u003ctbody\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eHEX1.00\u003c\/td\u003e\n              \u003ctd\u003eANKYLOS\u003c\/td\u003e\n              \u003ctd\u003eANKYLOS\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eHEX1.19\u003c\/td\u003e\n              \u003ctd\u003eANTHOGYR\u003c\/td\u003e\n              \u003ctd\u003eANTHOGYR · NOBEL BIOCARE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eHEX1.20\u003c\/td\u003e\n              \u003ctd\u003eOSSTEM\u003c\/td\u003e\n              \u003ctd\u003eOSSTEM · DIO-UF2 · C-Tech · MIS · 3I · MEGAGEN · ICM · T-PLUS · INNO · BICON · WARANTEC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eHEX1.25\u003c\/td\u003e\n              \u003ctd\u003eCORTEX\u003c\/td\u003e\n              \u003ctd\u003eCORTEX · ABT · ZIMMER\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eHEX1.27\u003c\/td\u003e\n              \u003ctd\u003eDENTIUM\u003c\/td\u003e\n              \u003ctd\u003eDENTIUM · DENTIS · CAMLOG · TICARE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eHEX1.40\u003c\/td\u003e\n              \u003ctd\u003eICX\u003c\/td\u003e\n              \u003ctd\u003eICX\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eNOB\u003c\/td\u003e\n              \u003ctd\u003eNOBEL\u003c\/td\u003e\n              \u003ctd\u003eNOBEL BIOCARE · BICON · BASIC · TAISAN\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eITI\u003c\/td\u003e\n              \u003ctd\u003eSTRAUMANN\u003c\/td\u003e\n              \u003ctd\u003eSTRAUMANN · ANTHOGYR · BICON\u003c\/td\u003e\n            \u003c\/tr\u003e\n          \u003c\/tbody\u003e\n        \u003c\/table\u003e\n      \u003c\/div\u003e\n\n      \u003cp class=\"kit-note\" style=\"margin-top:16px;\"\u003e\n        Compatibility is indicated by the manufacturer. Always confirm the correct driver and connection for your\n        specific implant system before use.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── WHAT'S INCLUDED ───────────────────────────────────────── --\u003e\n  \u003cdiv class=\"pd-section\"\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv class=\"pd-label\"\u003eWhat's Included\u003c\/div\u003e\n      \u003ch2 class=\"pd-h2\"\u003eIn the box\u003c\/h2\u003e\n      \u003cp class=\"pd-lead\"\u003eThe C-TW3 is supplied as a complete, ready-to-use set.\u003c\/p\u003e\n\n      \u003cdiv class=\"kit-table-wrap\"\u003e\n        \u003ctable class=\"kit-table\"\u003e\n          \u003cthead\u003e\n            \u003ctr\u003e\n              \u003cth\u003eComponent\u003c\/th\u003e\n              \u003cth\u003eQ'ty\u003c\/th\u003e\n            \u003c\/tr\u003e\n          \u003c\/thead\u003e\n          \u003ctbody\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eMotor Handpiece\u003c\/td\u003e\n              \u003ctd\u003e1\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eContra-angle (CX235C6)\u003c\/td\u003e\n              \u003ctd\u003e1\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eAC Adapter\u003c\/td\u003e\n              \u003ctd\u003e1\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eHandpiece Stand\u003c\/td\u003e\n              \u003ctd\u003e1\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eScrewdrivers\u003c\/td\u003e\n              \u003ctd\u003e16\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eO-Ring\u003c\/td\u003e\n              \u003ctd\u003e1\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eWrench\u003c\/td\u003e\n              \u003ctd\u003e1\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eSpray Nozzle\u003c\/td\u003e\n              \u003ctd\u003e1\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eUser Manual\u003c\/td\u003e\n              \u003ctd\u003e1\u003c\/td\u003e\n            \u003c\/tr\u003e\n          \u003c\/tbody\u003e\n        \u003c\/table\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── SPECIFICATIONS ────────────────────────────────────────── --\u003e\n  \u003cdiv class=\"pd-section pd-section--muted\"\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv class=\"pd-label\"\u003eSpecifications\u003c\/div\u003e\n      \u003ch2 class=\"pd-h2\"\u003eTechnical specifications\u003c\/h2\u003e\n\n      \u003ctable class=\"spec-table\"\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eDevice type\u003c\/td\u003e\n          \u003ctd\u003eElectric dental implant torque wrench (powered torque driver)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eTorque range\u003c\/td\u003e\n          \u003ctd\u003e10 – 55 N·cm (in 5 N·cm steps)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eTorque accuracy\u003c\/td\u003e\n          \u003ctd\u003e± 3 N·cm\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eSpeed range\u003c\/td\u003e\n          \u003ctd\u003e5 – 50 r\/min (in 5 r\/min steps)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eOperating modes\u003c\/td\u003e\n          \u003ctd\u003eStandard (constant speed) · Intelligent Deceleration\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eDirection\u003c\/td\u003e\n          \u003ctd\u003eForward \/ Reverse\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eTorque calibration\u003c\/td\u003e\n          \u003ctd\u003e15-second countdown (auto power-off after 3 min idle)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eMode of operation\u003c\/td\u003e\n          \u003ctd\u003eNon-continuous — 5 min on \/ 1 min off\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003ePower\u003c\/td\u003e\n          \u003ctd\u003eCordless — Rechargeable Li-ion battery (DC 3.7 V, 800 mAh)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eAC adapter\u003c\/td\u003e\n          \u003ctd\u003eInput AC 100 – 240 V, 50 \/ 60 Hz · Output 5 V ⎓ 2 A · 20 VA\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eApplied part\u003c\/td\u003e\n          \u003ctd\u003eContra-angle · Type B applied part\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eProtection class\u003c\/td\u003e\n          \u003ctd\u003eClass II (adapter)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eIngress protection\u003c\/td\u003e\n          \u003ctd\u003eIPX0\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eContra-angle\u003c\/td\u003e\n          \u003ctd\u003eSpeed ratio 320:1 · copper alloy (model CX235C6)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eMain unit dimensions\u003c\/td\u003e\n          \u003ctd\u003e24 × 21 × 131 mm · Max. grip Ø approx. 17 mm\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eMain unit weight\u003c\/td\u003e\n          \u003ctd\u003eApprox. 100 g\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003ePackage dimensions\u003c\/td\u003e\n          \u003ctd\u003e180 × 130 × 50 mm\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eSterilisation\u003c\/td\u003e\n          \u003ctd\u003eContra-angle autoclavable at 134 °C (steam) · motor handpiece \u0026amp; adapter: surface wipe only (not\n            autoclavable)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eManufacturer\u003c\/td\u003e\n          \u003ctd\u003eFoshan COXO Medical Instrument Co., Ltd.\u003c\/td\u003e\n        \u003c\/tr\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── OPERATING TIPS ────────────────────────────────────────── --\u003e\n  \u003cdiv class=\"pd-section\"\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv class=\"pd-label\"\u003eOperating Tips\u003c\/div\u003e\n      \u003ch2 class=\"pd-h2\"\u003eGetting the most from the C-TW3\u003c\/h2\u003e\n      \u003cp class=\"pd-lead\"\u003ePractical guidance for precise, repeatable torque at the chairside.\u003c\/p\u003e\n\n      \u003cdiv class=\"tips-list\"\u003e\n\n        \u003cdiv class=\"tip-item\"\u003e\n          \u003cdiv class=\"tip-num\"\u003e1\u003c\/div\u003e\n          \u003cdiv class=\"tip-body\"\u003e\n\u003cstrong\u003eLet the auto-calibration finish before you start.\u003c\/strong\u003e After switching on,\n            the device runs a 15-second calibration countdown. Allow it to complete so the torque reading is accurate\n            for the case ahead.\u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"tip-item\"\u003e\n          \u003cdiv class=\"tip-num\"\u003e2\u003c\/div\u003e\n          \u003cdiv class=\"tip-body\"\u003e\n\u003cstrong\u003eSet torque to the implant manufacturer's value.\u003c\/strong\u003e Choose the target in\n            5 N·cm steps to match the fixture or abutment specification. The ±3 N·cm accuracy means the set value is\n            what\n            the device delivers — avoid exceeding the manufacturer's recommended torque.\u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"tip-item\"\u003e\n          \u003cdiv class=\"tip-num\"\u003e3\u003c\/div\u003e\n          \u003cdiv class=\"tip-body\"\u003e\n\u003cstrong\u003eUse Intelligent Deceleration for final seating.\u003c\/strong\u003e For the last stage of\n            abutment or fixture seating, the deceleration mode slows the driver as it nears the target — giving a\n            smoother, more controlled finish than a constant-speed stop.\u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"tip-item\"\u003e\n          \u003cdiv class=\"tip-num\"\u003e4\u003c\/div\u003e\n          \u003cdiv class=\"tip-body\"\u003e\n\u003cstrong\u003eRotate the head for a straight line of approach.\u003c\/strong\u003e Adjust the handpiece\n            head so the driver meets the screw axis squarely, especially in the posterior — a straight approach keeps\n            the torque reading true and protects the screw head.\u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"tip-item\"\u003e\n          \u003cdiv class=\"tip-num\"\u003e5\u003c\/div\u003e\n          \u003cdiv class=\"tip-body\"\u003e\n\u003cstrong\u003eSterilise the right parts the right way.\u003c\/strong\u003e The contra-angle must be\n            cleaned, disinfected and steam-sterilised at 134 °C before first use and between patients — and, per the\n            Instructions for Use, all patient-contact parts should be cleaned and sterilised before use. The motor\n            handpiece and AC adapter must \u003cem\u003enot\u003c\/em\u003e be autoclaved or immersed — wipe their surfaces with a 75%\n            alcohol or approved disinfectant wipe only.\u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"tip-item\"\u003e\n          \u003cdiv class=\"tip-num\"\u003e6\u003c\/div\u003e\n          \u003cdiv class=\"tip-body\"\u003e\n\u003cstrong\u003eCharge between cases, and handle with care.\u003c\/strong\u003e Recharge via the AC adapter\n            when the battery is low (do not operate while charging). Power the device off before changing the\n            contra-angle or a screwdriver, and never use it as a manual ratchet — forcing it by hand can damage the\n            internal gear.\u003c\/div\u003e\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"tip-warn\"\u003e\n        \u003cstrong\u003e⚠ Clinical Notice:\u003c\/strong\u003e The C-TW3 is intended for professional dental use only, for controlled\n        torque delivery in implant and related procedures. It is \u003cstrong\u003econtraindicated for patients with cardiac\n          pacemakers or other implanted electronic devices\u003c\/strong\u003e, and should be used with caution in patients with\n        heart disease, pregnant women and children. Always set torque to the implant manufacturer's specified value,\n        confirm compatibility of drivers and connections, and follow the Instructions for Use for operation, cleaning,\n        sterilisation and maintenance requirements.\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e","brand":"COXO","offers":[{"title":"Default Title","offer_id":67668455653666,"sku":"C-TW3","price":1000.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/coxo-torque-wrench-c-tw3.png?v=1793605383","url":"https:\/\/xdentalsupplies.com.au\/products\/coxo-electric-torque-wrench","provider":"X Dental Supplies","version":"1.0","type":"link"}