{"product_id":"r-brush","title":"NeoBiotech R-Brush","description":"\u003cdiv\u003e\n    \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/Hero-RBrush.png?v=1782700708\" style=\"display:block;max-width:100%;justify-self:center;\" alt=\"Neobiotech R-Brush Peri-Implantitis Round Brush\"\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── HERO ──────────────────────────────────────────────────── --\u003e\n  \u003cdiv class=\"pd-hero\"\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv class=\"pd-hero-tag\"\u003eNeobiotech · Peri-Implantitis\u003c\/div\u003e\n      \u003ch1 class=\"pd-hero-title\"\u003eR-Brush\u003cbr\u003eRound Brush for Implant Surface Decontamination\u003c\/h1\u003e\n      \u003cp class=\"pd-hero-sub\"\u003e\n        A rotating round brush designed to thoroughly cleanse the infected implant surface in peri-implantitis\n        treatment. R-Brush's circular bristle arrangement covers the full circumference of the exposed implant\n        threads, removing contamination and granulation tissue while preserving the implant's rough surface\n        architecture for re-osseointegration.\n      \u003c\/p\u003e\n      \u003cdiv class=\"pd-hero-badges\"\u003e\n        \u003cspan class=\"pd-hero-badge\"\u003e\n          \u003csvg viewbox=\"0 0 16 16\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.8\"\u003e\n            \u003ccircle cx=\"8\" cy=\"8\" r=\"6.5\"\u003e\u003c\/circle\u003e\n            \u003cpath d=\"M5 8.5l2 2 4-4\"\u003e\u003c\/path\u003e\n          \u003c\/svg\u003e\n          Perfect Implant Surface Cleansing\n        \u003c\/span\u003e\n        \u003cspan class=\"pd-hero-badge\"\u003e\n          \u003csvg viewbox=\"0 0 16 16\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.8\"\u003e\n            \u003cpath d=\"M3 12l4-4 3 3 4-5\"\u003e\u003c\/path\u003e\n          \u003c\/svg\u003e\n          2,000–5,000 rpm\n        \u003c\/span\u003e\n        \u003cspan class=\"pd-hero-badge\"\u003e\n          \u003csvg viewbox=\"0 0 16 16\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.8\"\u003e\n            \u003cpath d=\"M8 2v12M2 8h12\"\u003e\u003c\/path\u003e\n          \u003c\/svg\u003e\n          Regular Ø5.6 · Wide Ø6.6\n        \u003c\/span\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── CLINICAL INSIGHT ──────────────────────────────────────── --\u003e\n  \u003cdiv class=\"pd-section\"\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv class=\"pd-label\"\u003eClinical Insight\u003c\/div\u003e\n      \u003ch2 class=\"pd-h2\"\u003eWhat clinicians are saying\u003c\/h2\u003e\n      \u003cp class=\"pd-lead\"\u003eReal-world feedback from implantologists using R-Brush in peri-implantitis surgical\n        treatment.\u003c\/p\u003e\n\n      \u003cdiv class=\"insights-grid\"\u003e\n        \u003cdiv class=\"insight-card\"\u003e\n          \u003cp class=\"insight-quote\"\u003e\n            \"The round design is what makes R-Brush the right tool for this job — you're working around a\n            cylinder, and a cylindrical brush is the only way to achieve full circumferential contact on every\n            thread in a single pass. I've used it in cases where the exposed surface looked irretrievable and\n            the SEM comparison images we've seen in training show exactly what it achieves. The surface comes\n            up clean in a way that gives re-osseointegration a genuine chance.\"\n          \u003c\/p\u003e\n          \u003cdiv class=\"insight-tag\"\u003ePeri-implantitis Surgery · Surface Decontamination · Re-osseointegration\u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"insight-card\"\u003e\n          \u003cp class=\"insight-quote\"\u003e\n            \"Peri-implantitis surgical management needs a decontamination step that's fast, complete, and\n            doesn't compromise the surface for healing. R-Brush handles all three. It's straightforward to\n            use — connect the cover cap, insert into the surgical site, apply with vertical reciprocating\n            motion at the right rpm, irrigate throughout. The before\/after on the implant surface is\n            visible clinically, not just under an electron microscope.\"\n          \u003c\/p\u003e\n          \u003cdiv class=\"insight-tag\"\u003eSurgical Workflow · Mechanical Decontamination · Irrigation Protocol\u003c\/div\u003e\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── RESOURCES ─────────────────────────────────────────────── --\u003e\n  \u003cdiv class=\"pd-section pd-section--muted\"\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv class=\"pd-label\"\u003eResources\u003c\/div\u003e\n      \u003ch2 class=\"pd-h2\"\u003eClinical Documentation\u003c\/h2\u003e\n      \u003cdiv class=\"dl-grid\"\u003e\n        \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/NeoBioTech_Brush_Article_Collection.pdf?v=1733813262\" class=\"dl-btn\" target=\"_blank\"\u003e\n          \u003csvg viewbox=\"0 0 16 16\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.8\"\u003e\n            \u003cpath d=\"M3 13h10M8 2v8M5 7l3 3 3-3\"\u003e\u003c\/path\u003e\n          \u003c\/svg\u003e\n          Article Collection\n        \u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── INDICATIONS ───────────────────────────────────────────── --\u003e\n  \u003cdiv class=\"pd-section\"\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv style=\"border-radius:12px;overflow:hidden;line-height:0;\"\u003e\n        \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/RBrush-img.png?v=1782704759\" style=\"display:block;width:100%;max-width:100%;\" alt=\"NeoBiotech R-Brush\"\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv class=\"pd-label\"\u003eIndications\u003c\/div\u003e\n      \u003ch2 class=\"pd-h2\"\u003eWhen to use R-Brush\u003c\/h2\u003e\n      \u003cp class=\"pd-lead\"\u003eDesigned for the mechanical decontamination of exposed implant surfaces in surgical\n        peri-implantitis treatment — where thorough, circumferential cleansing is required across the full\n        extent of the infected threads.\u003c\/p\u003e\n\n      \u003cdiv class=\"use-grid\"\u003e\n\n        \u003cdiv class=\"use-item\"\u003e\n          \u003cdiv class=\"use-icon\"\u003e\n            \u003csvg viewbox=\"0 0 20 20\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.6\"\u003e\n              \u003ccircle cx=\"10\" cy=\"10\" r=\"7\"\u003e\u003c\/circle\u003e\n              \u003cpath d=\"M10 7v4M10 13v1\"\u003e\u003c\/path\u003e\n            \u003c\/svg\u003e\n          \u003c\/div\u003e\n          \u003cdiv class=\"use-text\"\u003e\n\u003cstrong\u003ePeri-implantitis Surgical Therapy\u003c\/strong\u003e — Applied after flap\n            elevation and granulation tissue removal to mechanically decontaminate the exposed implant\n            surface prior to guided bone regeneration or resective surgery.\u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"use-item\"\u003e\n          \u003cdiv class=\"use-icon\"\u003e\n            \u003csvg viewbox=\"0 0 20 20\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.6\"\u003e\n              \u003cpath d=\"M4 16l4-4 4 4 4-6\"\u003e\u003c\/path\u003e\n            \u003c\/svg\u003e\n          \u003c\/div\u003e\n          \u003cdiv class=\"use-text\"\u003e\n\u003cstrong\u003eImplant Surface Biofilm Removal\u003c\/strong\u003e — Removes infected tissue\n            and biofilm from the full circumference of exposed implant threads using rotating round bristles,\n            covering areas that linear or angled brushes cannot reach uniformly.\u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"use-item\"\u003e\n          \u003cdiv class=\"use-icon\"\u003e\n            \u003csvg viewbox=\"0 0 20 20\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.6\"\u003e\n              \u003cpath d=\"M10 3v14M4 10h12\"\u003e\u003c\/path\u003e\n            \u003c\/svg\u003e\n          \u003c\/div\u003e\n          \u003cdiv class=\"use-text\"\u003e\n\u003cstrong\u003eRe-osseointegration Preparation\u003c\/strong\u003e — Surface cleansing with\n            R-Brush preserves the rough implant surface architecture — a critical factor for new bone contact\n            and re-osseointegration following decontamination.\u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"use-item\"\u003e\n          \u003cdiv class=\"use-icon\"\u003e\n            \u003csvg viewbox=\"0 0 20 20\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.6\"\u003e\n              \u003crect x=\"3\" y=\"5\" width=\"14\" height=\"10\" rx=\"2\"\u003e\u003c\/rect\u003e\n              \u003cpath d=\"M8 5V3m4 2V3\"\u003e\u003c\/path\u003e\n            \u003c\/svg\u003e\n          \u003c\/div\u003e\n          \u003cdiv class=\"use-text\"\u003e\n\u003cstrong\u003eWide-diameter Implant Sites\u003c\/strong\u003e — Two diameter options (Regular\n            Ø5.6 and Wide Ø6.6) allow appropriate brush selection for standard and wide-platform implants,\n            ensuring bristle contact across the thread profile without excessive lateral pressure.\u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"use-item\"\u003e\n          \u003cdiv class=\"use-icon\"\u003e\n            \u003csvg viewbox=\"0 0 20 20\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.6\"\u003e\n              \u003cpath d=\"M10 4a6 6 0 100 12A6 6 0 0010 4zM10 4v2M10 14v2M4 10H2M18 10h-2\"\u003e\u003c\/path\u003e\n            \u003c\/svg\u003e\n          \u003c\/div\u003e\n          \u003cdiv class=\"use-text\"\u003e\n\u003cstrong\u003eGranulation Tissue Removal\u003c\/strong\u003e — The rotating bristle action\n            removes granulation tissue from the implant surface and around the threads during peri-implantitis\n            surgical debridement.\u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"use-item\"\u003e\n          \u003cdiv class=\"use-icon\"\u003e\n            \u003csvg viewbox=\"0 0 20 20\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.6\"\u003e\n              \u003cpath d=\"M5 15l3-6 2 3 2-5 3 8\"\u003e\u003c\/path\u003e\n              \u003cpath d=\"M3 17h14\"\u003e\u003c\/path\u003e\n            \u003c\/svg\u003e\n          \u003c\/div\u003e\n          \u003cdiv class=\"use-text\"\u003e\n\u003cstrong\u003eCombined Peri-implantitis Protocol\u003c\/strong\u003e — Used as the mechanical\n            decontamination step within a comprehensive peri-implantitis surgical protocol, typically followed\n            by chemical decontamination, bone grafting, and membrane placement where indicated.\u003c\/div\u003e\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── PRODUCT VIDEO ─────────────────────────────────────────── --\u003e\n  \u003cdiv class=\"pd-section pd-section--muted\"\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv class=\"pd-label\"\u003eProduct Video\u003c\/div\u003e\n      \u003ch2 class=\"pd-h2\"\u003eR-Brush in surgical use\u003c\/h2\u003e\n      \u003cp class=\"pd-lead\"\u003eSee the R-Brush protocol applied in a peri-implantitis surgical case — from cover cap\n        placement to post-decontamination surface assessment.\u003c\/p\u003e\n      \u003cdiv style=\"max-width:100%;margin:24px auto 0;\"\u003e\n        \u003cdiv style=\"position:relative;width:100%;padding-top:56.25%;\"\u003e\n          \u003ciframe title=\"NeoBiotech R-Brush\" src=\"https:\/\/www.youtube.com\/embed\/vTG3B1Hsm_g?si=PPL2lzSS1Ftstach_\u0026amp;autoplay=1\u0026amp;mute=1\u0026amp;playsinline=1\u0026amp;modestbranding=1\u0026amp;rel=0\" allowfullscreen=\"\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" frameborder=\"0\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0;\"\u003e\u003c\/iframe\u003e\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── KEY FEATURES \/ SEM EVIDENCE ──────────────────────────── --\u003e\n  \u003cdiv class=\"pd-section\"\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv class=\"pd-label\"\u003eSurface Cleansing\u003c\/div\u003e\n      \u003ch2 class=\"pd-h2\"\u003eBefore \u0026amp; after — confirmed under electron microscopy\u003c\/h2\u003e\n      \u003cp class=\"pd-lead\"\u003eSEM imaging at X100, X500, and X5000 magnification demonstrates the change in implant\n        surface condition following R-Brush decontamination.\u003c\/p\u003e\n\n      \u003c!-- Before \/ After SEM image block --\u003e\n      \u003cdiv style=\"display:grid;grid-template-columns:1fr 1fr;gap:20px;margin:28px 0;\"\u003e\n\n        \u003cdiv style=\"background:#f5f5f5;border-radius:12px;padding:20px;\"\u003e\n          \u003cp style=\"font-size:0.85em;font-weight:700;text-transform:uppercase;letter-spacing:.08em;color:#888;margin-bottom:12px;\"\u003e\n            Before R-Brush\u003c\/p\u003e\n          \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/RBrush_before.png?v=1782701879\" style=\"display:block;width:100%;border-radius:8px;\" alt=\"Implant surface before R-Brush — SEM at X100, X500, X5000\"\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv style=\"background:#f5f5f5;border-radius:12px;padding:20px;\"\u003e\n          \u003cp style=\"font-size:0.85em;font-weight:700;text-transform:uppercase;letter-spacing:.08em;color:#888;margin-bottom:12px;\"\u003e\n            After R-Brush\u003c\/p\u003e\n          \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/RBrush_after.png?v=1782701876\" style=\"display:block;width:100%;border-radius:8px;\" alt=\"Implant surface after R-Brush — SEM at X100, X500, X5000\"\u003e\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── CLINICAL CASE ─────────────────────────────────────────── --\u003e\n  \u003cdiv class=\"pd-section pd-section--muted\"\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv class=\"pd-label\"\u003eClinical Case\u003c\/div\u003e\n      \u003ch2 class=\"pd-h2\"\u003eR-Brush in clinical use\u003c\/h2\u003e\n      \u003cp class=\"pd-lead\"\u003eA peri-implantitis case demonstrating the R-Brush decontamination protocol — from\n        prosthesis removal to post-treatment surface assessment.\u003c\/p\u003e\n\n      \u003cdiv class=\"case-block\"\u003e\n        \u003ch4 class=\"case-indication\"\u003eSevere Peri-implantitis — Mechanical Surface Decontamination\u003c\/h4\u003e\n        \u003cp class=\"case-sub\"\u003eSevere peri-implantitis with bone loss — R-Brush applied to exposed implant surface,\n          confirmed clean post-treatment\u003c\/p\u003e\n\n        \u003cdiv class=\"case-gallery\"\u003e\n\n          \u003cdiv class=\"case-img-wrap\"\u003e\n            \u003cdiv class=\"case-step\"\u003e\n              \u003cdiv class=\"case-step-num\"\u003e1\u003c\/div\u003e\n              \u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/RBrush-Case_1.png?v=1782697947\" alt=\"Severe peri-implantitis and bone loss observed — prosthesis removed\"\u003e\u003c\/div\u003e\n            \u003c\/div\u003e\n            \u003cp class=\"case-caption\"\u003eSevere peri-implantitis and bone loss observed — prosthesis removed\u003c\/p\u003e\n          \u003c\/div\u003e\n\n          \u003cdiv class=\"case-img-wrap\"\u003e\n            \u003cdiv class=\"case-step\"\u003e\n              \u003cdiv class=\"case-step-num\"\u003e2\u003c\/div\u003e\n              \u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/RBrush-Case_2.png?v=1782697947\" alt=\"Cover cap connected to fixture prior to R-Brush application\"\u003e\u003c\/div\u003e\n            \u003c\/div\u003e\n            \u003cp class=\"case-caption\"\u003eCover cap connected to fixture\u003c\/p\u003e\n          \u003c\/div\u003e\n\n          \u003cdiv class=\"case-img-wrap\"\u003e\n            \u003cdiv class=\"case-step\"\u003e\n              \u003cdiv class=\"case-step-num\"\u003e3\u003c\/div\u003e\n              \u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/RBrush-Case_3.png?v=1782697947\" alt=\"R-Brush applied along exposed implant surface at 2,000–5,000 rpm\"\u003e\u003c\/div\u003e\n            \u003c\/div\u003e\n            \u003cp class=\"case-caption\"\u003eR-Brush applied at 2,000–5,000 rpm with irrigation\u003c\/p\u003e\n          \u003c\/div\u003e\n\n          \u003cdiv class=\"case-img-wrap\"\u003e\n            \u003cdiv class=\"case-step\"\u003e\n              \u003cdiv class=\"case-step-num\"\u003e4\u003c\/div\u003e\n              \u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/RBrush-Case_4.png?v=1782697947\" alt=\"Implant surface perfectly cleansed after R-Brush use\"\u003e\u003c\/div\u003e\n            \u003c\/div\u003e\n            \u003cp class=\"case-caption\"\u003eImplant surface perfectly cleansed\u003c\/p\u003e\n          \u003c\/div\u003e\n\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── SPECIFICATIONS ─────────────────────────────────────────── --\u003e\n  \u003cdiv class=\"pd-section\"\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv class=\"pd-label\"\u003eSpecifications\u003c\/div\u003e\n      \u003ch2 class=\"pd-h2\"\u003eTechnical specifications\u003c\/h2\u003e\n\n      \u003ctable class=\"spec-table\"\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eDevice type\u003c\/td\u003e\n          \u003ctd\u003eRound brush for implant surface decontamination — peri-implantitis treatment\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eAvailable diameters\u003c\/td\u003e\n          \u003ctd\u003eRegular Ø5.6 · Wide Ø6.6\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eOperating speed\u003c\/td\u003e\n          \u003ctd\u003e2,000–5,000 rpm with irrigation (1:1 handpiece)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eApplication method\u003c\/td\u003e\n          \u003ctd\u003eVertical reciprocating motion along exposed implant surface — cover cap connected to fixture prior to use\n          \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eManufacturer\u003c\/td\u003e\n          \u003ctd\u003eNeobiotech Co., Ltd\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eOrigin\u003c\/td\u003e\n          \u003ctd\u003eMade in Korea\u003c\/td\u003e\n        \u003c\/tr\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── CLINICAL TIPS ──────────────────────────────────────────── --\u003e\n  \u003cdiv class=\"pd-section\"\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv class=\"pd-label\"\u003eClinical Tips\u003c\/div\u003e\n      \u003ch2 class=\"pd-h2\"\u003eGetting the most from R-Brush\u003c\/h2\u003e\n      \u003cp class=\"pd-lead\"\u003ePractical guidance for effective peri-implantitis surface decontamination.\u003c\/p\u003e\n\n      \u003cdiv class=\"tips-list\"\u003e\n        \u003cdiv class=\"tip-item\"\u003e\n          \u003cdiv class=\"tip-num\"\u003e1\u003c\/div\u003e\n          \u003cdiv class=\"tip-body\"\u003e\n\u003cstrong\u003eConnect the cover cap to the fixture before applying the brush.\u003c\/strong\u003e\n            The cover cap protects the internal implant connection from bristle contact during the decontamination\n            procedure. Confirm the cover cap is fully seated and secure before engaging the R-Brush — loose\n            seating risks displacing the cap into the surgical field or damaging the internal hex.\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"tip-item\"\u003e\n          \u003cdiv class=\"tip-num\"\u003e2\u003c\/div\u003e\n          \u003cdiv class=\"tip-body\"\u003e\n\u003cstrong\u003eSelect the brush diameter to match the implant platform.\u003c\/strong\u003e\n            The Regular (Ø5.6) is appropriate for standard-diameter implants; the Wide (Ø6.6) for wide-platform\n            fixtures. Correct diameter selection ensures the bristles engage the thread profile across the full\n            circumference without excessive radial pressure on the surrounding bone wall.\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"tip-item\"\u003e\n          \u003cdiv class=\"tip-num\"\u003e3\u003c\/div\u003e\n          \u003cdiv class=\"tip-body\"\u003e\n\u003cstrong\u003eUse vertical reciprocating motion with copious irrigation throughout.\u003c\/strong\u003e\n            Apply the R-Brush along the exposed implant surface with a continuous vertical reciprocating\n            stroke at 2,000–5,000 rpm. Maintain irrigation throughout — dry use generates heat at the\n            implant surface and risks thermal damage to the remaining peri-implant bone.\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"tip-item\"\u003e\n          \u003cdiv class=\"tip-num\"\u003e4\u003c\/div\u003e\n          \u003cdiv class=\"tip-body\"\u003e\n\u003cstrong\u003eUse R-Brush as part of a comprehensive decontamination protocol.\u003c\/strong\u003e\n            Mechanical decontamination with R-Brush addresses biofilm and granulation tissue on the implant\n            surface, but optimal peri-implantitis outcomes are achieved when combined with appropriate\n            chemical decontamination, guided bone regeneration where indicated, and long-term supportive\n            peri-implant maintenance.\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"tip-item\"\u003e\n          \u003cdiv class=\"tip-num\"\u003e5\u003c\/div\u003e\n          \u003cdiv class=\"tip-body\"\u003e\n\u003cstrong\u003eSingle patient use — do not resterilise or reuse.\u003c\/strong\u003e\n            R-Brush is a single-use disposable device. Reuse risks cross-contamination and bristle fatigue,\n            which reduces decontamination efficacy and may result in bristle separation in the surgical field.\n            Discard after each patient.\u003c\/div\u003e\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"tip-warn\"\u003e\n        \u003cstrong\u003e⚠ Clinical Notice:\u003c\/strong\u003e R-Brush is intended for use by trained dental surgeons in\n        peri-implantitis surgical procedures. Always connect the cover cap to the fixture prior to use.\n        Use with copious irrigation at 2,000–5,000 rpm — do not exceed the recommended speed range.\n        Single patient use only — do not reuse. Follow AS\/NZS sterilisation and infection control guidelines\n        for all surgical instruments used in the same procedure. Refer to product labelling for full\n        indications, contraindications, and handling instructions.\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e","brand":"Neobiotech","offers":[{"title":"Regular","offer_id":51607167631650,"sku":"RB440","price":250.0,"currency_code":"AUD","in_stock":true},{"title":"Wide","offer_id":51607167664418,"sku":"RB540","price":250.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/RBrush-1.png?v=1732061537","url":"https:\/\/xdentalsupplies.com.au\/products\/r-brush","provider":"X Dental Supplies","version":"1.0","type":"link"}