{"product_id":"sinus-crestal-approach-kit","title":"NeoBiotech Sinus Crestal Approach Kit","description":"\u003cdiv\u003e\n    \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/SCA-Hero.png?v=1785375034\" style=\"display:block;max-width:100%;justify-self:center;\" alt=\"Neobiotech SCA Kit — Sinus Crestal Approach Kit with all components\"\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── HERO ──────────────────────────────────────────────────── --\u003e\n  \u003cdiv class=\"pd-hero\"\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv class=\"pd-hero-tag\"\u003eNeobiotech · Sinus Lift\u003c\/div\u003e\n      \u003ch1 class=\"pd-hero-title\"\u003eSCA Kit\u003cbr\u003eSinus Crestal Approach Kit\u003c\/h1\u003e\n      \u003cp class=\"pd-hero-sub\"\u003e\n        A complete surgical kit for crestal sinus elevation — perforating the sinus inferior\n        cortical wall and lifting the Schneiderian membrane without membrane damage or the\n        need for mallet osteotome technique. The S-Reamer's uniquely designed blade structure\n        forms a protective bone disk against the membrane, enabling safe, high-speed drilling\n        at 1,200 RPM even in misaligned and septum cases.\n      \u003c\/p\u003e\n      \u003cdiv class=\"pd-hero-badges\"\u003e\n        \u003cspan class=\"pd-hero-badge\"\u003e\n          \u003csvg viewbox=\"0 0 16 16\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.8\"\u003e\n            \u003ccircle cx=\"8\" cy=\"8\" r=\"6.5\"\u003e\u003c\/circle\u003e\n            \u003cpath d=\"M5 8.5l2 2 4-4\"\u003e\u003c\/path\u003e\n          \u003c\/svg\u003e\n          No Mallet — No Membrane Tear\n        \u003c\/span\u003e\n        \u003cspan class=\"pd-hero-badge\"\u003e\n          \u003csvg viewbox=\"0 0 16 16\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.8\"\u003e\n            \u003cpath d=\"M3 12l4-4 3 3 4-5\"\u003e\u003c\/path\u003e\n          \u003c\/svg\u003e\n          S-Reamer 1,200 RPM · Bone Disk Protection\n        \u003c\/span\u003e\n        \u003cspan class=\"pd-hero-badge\"\u003e\n          \u003csvg viewbox=\"0 0 16 16\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.8\"\u003e\n            \u003cpath d=\"M8 2v12M2 8h12\"\u003e\u003c\/path\u003e\n          \u003c\/svg\u003e\n          CMI Fixation — Tri-cortical Stability\n        \u003c\/span\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── CLINICAL INSIGHT ──────────────────────────────────────── --\u003e\n  \u003cdiv class=\"pd-section\"\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv class=\"pd-label\"\u003eClinical Insight\u003c\/div\u003e\n      \u003ch2 class=\"pd-h2\"\u003eWhat clinicians are saying\u003c\/h2\u003e\n      \u003cp class=\"pd-lead\"\u003eReal-world feedback from implantologists using the SCA Kit for crestal\n        sinus elevation in their surgical practice.\u003c\/p\u003e\n\n      \u003cdiv class=\"insights-grid\"\u003e\n        \u003cdiv class=\"insight-card\"\u003e\n          \u003cp class=\"insight-quote\"\u003e\n            \"The SCA Kit has changed how I approach short residual bone cases. The S-Reamer\n            drills at speed — you're not hammering an osteotome, so patient feedback is\n            completely different. The bone disk that forms in the reamer head is what really\n            makes the difference clinically: even when I've had the reamer touch the membrane\n            directly in a septum case, there's been no perforation. It's built more confidence\n            into what used to be a high-anxiety step of the procedure.\"\n          \u003c\/p\u003e\n          \u003cdiv class=\"insight-tag\"\u003eCrestal Approach · Septum Case · Bone Disk Protection\u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"insight-card\"\u003e\n          \u003cp class=\"insight-quote\"\u003e\n            \"CMI fixation was the concept that made me try the SCA Kit — getting engagement\n            in all three bone zones from a crestal approach is something conventional\n            osteotome technique simply doesn't achieve reliably. The stopper system makes\n            sequential depth progression feel controlled and safe, and the whole procedure\n            from initial drill to final implant placement follows a logical step-by-step\n            sequence that's easy to train staff and residents on.\"\n          \u003c\/p\u003e\n          \u003cdiv class=\"insight-tag\"\u003eCMI Fixation · Depth Control · Operator Training\u003c\/div\u003e\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── INDICATIONS ───────────────────────────────────────────── --\u003e\n  \u003cdiv class=\"pd-section pd-section--muted\"\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv class=\"pd-label\"\u003eIndications\u003c\/div\u003e\n      \u003ch2 class=\"pd-h2\"\u003eWhen to use the SCA Kit\u003c\/h2\u003e\n      \u003cp class=\"pd-lead\"\u003eIndicated for crestal sinus elevation in cases where residual bone\n        height is insufficient for standard implant length — without the need for lateral\n        window approach or mallet technique.\u003c\/p\u003e\n\n      \u003cdiv class=\"use-grid\"\u003e\n\n        \u003cdiv class=\"use-item\"\u003e\n          \u003cdiv class=\"use-icon\"\u003e\n            \u003csvg viewbox=\"0 0 20 20\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.6\"\u003e\n              \u003cpath d=\"M10 3c0 0-5 3-5 8a5 5 0 0010 0c0-5-5-8-5-8z\"\u003e\u003c\/path\u003e\n              \u003cpath d=\"M10 11v3M8 13h4\"\u003e\u003c\/path\u003e\n            \u003c\/svg\u003e\n          \u003c\/div\u003e\n          \u003cdiv class=\"use-text\"\u003e\n\u003cstrong\u003eCrestal Sinus Elevation\u003c\/strong\u003e — Posterior maxillary\n            implant sites with insufficient residual bone height requiring sinus floor\n            elevation via the transcrestal (crestal) approach without lateral window\n            surgery.\u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"use-item\"\u003e\n          \u003cdiv class=\"use-icon\"\u003e\n            \u003csvg viewbox=\"0 0 20 20\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.6\"\u003e\n              \u003cpath d=\"M4 16l4-4 4 4 4-6\"\u003e\u003c\/path\u003e\n              \u003ccircle cx=\"16\" cy=\"5\" r=\"2\"\u003e\u003c\/circle\u003e\n            \u003c\/svg\u003e\n          \u003c\/div\u003e\n          \u003cdiv class=\"use-text\"\u003e\n\u003cstrong\u003eMisaligned \u0026amp; Septum Cases\u003c\/strong\u003e — The S-Reamer's\n            'S'-shaped blade design and bone disk mechanism allow safe perforation even in\n            cases with a misaligned sinus floor or septum — conditions that increase\n            membrane perforation risk with conventional osteotome technique.\u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"use-item\"\u003e\n          \u003cdiv class=\"use-icon\"\u003e\n            \u003csvg viewbox=\"0 0 20 20\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.6\"\u003e\n              \u003cpath d=\"M3 17l4-8 3 4 2-6 4 10\"\u003e\u003c\/path\u003e\n            \u003c\/svg\u003e\n          \u003c\/div\u003e\n          \u003cdiv class=\"use-text\"\u003e\n\u003cstrong\u003eCMI Fixation Cases\u003c\/strong\u003e — Where tri-cortical initial\n            stability is required: simultaneous engagement in the crestal cortical bone,\n            middle cancellous bone, and sinus inferior cortical bone in a single\n            implant placement.\u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"use-item\"\u003e\n          \u003cdiv class=\"use-icon\"\u003e\n            \u003csvg viewbox=\"0 0 20 20\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.6\"\u003e\n              \u003crect x=\"3\" y=\"6\" width=\"14\" height=\"9\" rx=\"2\"\u003e\u003c\/rect\u003e\n              \u003cpath d=\"M7 6V4m6 2V4M3 10h14\"\u003e\u003c\/path\u003e\n            \u003c\/svg\u003e\n          \u003c\/div\u003e\n          \u003cdiv class=\"use-text\"\u003e\n\u003cstrong\u003eSimultaneous Implant Placement\u003c\/strong\u003e — Single-stage\n            crestal elevation and implant placement at the same surgical visit, where\n            residual bone height and density support immediate fixture insertion following\n            sinus floor preparation.\u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"use-item\"\u003e\n          \u003cdiv class=\"use-icon\"\u003e\n            \u003csvg viewbox=\"0 0 20 20\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.6\"\u003e\n              \u003cpath d=\"M10 4a6 6 0 100 12A6 6 0 0010 4zM10 4v2M10 14v2M4 10H2M18 10h-2\"\u003e\u003c\/path\u003e\n            \u003c\/svg\u003e\n          \u003c\/div\u003e\n          \u003cdiv class=\"use-text\"\u003e\n\u003cstrong\u003eMinimally Invasive Sinus Augmentation\u003c\/strong\u003e — Where\n            a less traumatic alternative to the lateral window approach is preferred —\n            reducing patient morbidity, shortening operative time, and improving\n            post-operative comfort.\u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"use-item\"\u003e\n          \u003cdiv class=\"use-icon\"\u003e\n            \u003csvg viewbox=\"0 0 20 20\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.6\"\u003e\n              \u003cpath d=\"M5 15l3-6 2 3 2-5 3 8\"\u003e\u003c\/path\u003e\n              \u003cpath d=\"M3 17h14\"\u003e\u003c\/path\u003e\n            \u003c\/svg\u003e\n          \u003c\/div\u003e\n          \u003cdiv class=\"use-text\"\u003e\n\u003cstrong\u003eCrestal Bone Grafting\u003c\/strong\u003e — Bone grafting material\n            is placed via the transcrestal osteotomy site using the Bone Carrier, Bone\n            Condenser, Bone Inserter, and Bone Spreader — elevating the membrane and\n            building sinus floor volume without open sinus access.\u003c\/div\u003e\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── FEATURE HIGHLIGHTS — 3S ──────────────────────────────── --\u003e\n  \u003cdiv class=\"pd-section\"\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv class=\"pd-label\"\u003eThe 3S of SCA Kit\u003c\/div\u003e\n      \u003ch2 class=\"pd-h2\"\u003eSafety · Speedy · Simple\u003c\/h2\u003e\n      \u003cp class=\"pd-lead\"\u003eThree design principles behind the SCA Kit — each directly addressing a\n        clinical limitation of conventional crestal sinus elevation technique.\u003c\/p\u003e\n\n      \u003cdiv class=\"feature-block\"\u003e\n        \u003cdiv class=\"feature-media\"\u003e\n          \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/SCA-Features_1.png?v=1785375035\" alt=\"SCA Kit Safety — bone disk formed between S-Reamer head and sinus membrane provides additional membrane protection\"\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"feature-copy\"\u003e\n          \u003cp class=\"feature-tag\"\u003eSafety\u003c\/p\u003e\n          \u003ch3 class=\"feature-headline\"\u003eBone disk shields the membrane\u003cbr\u003e— even on direct contact\u003c\/h3\u003e\n          \u003cdiv class=\"pillar-desc\"\u003e\n            \u003cp\u003eThe S-Reamer's specially designed blade structure does not tear the sinus\n              membrane even in direct contact. During drilling, bone chips fill the reamer\n              head space and form a flat bone disk surface between the reamer and the\n              membrane — providing an additional protective layer. This makes the SCA Kit\n              safe to use in misaligned and septum cases where membrane contact risk\n              is highest.\u003c\/p\u003e\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"feature-block reverse\"\u003e\n        \u003cdiv class=\"feature-media\"\u003e\n          \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/SCA-Features_2.png?v=1785375034\" alt=\"SCA Kit Speedy — S-Reamer high-speed drilling at 1,200 RPM with irrigation for rapid sinus wall perforation\"\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"feature-copy\"\u003e\n          \u003cp class=\"feature-tag\"\u003eSpeedy\u003c\/p\u003e\n          \u003ch3 class=\"feature-headline\"\u003eHigh-speed drilling\u003cbr\u003e— 1,200 RPM with irrigation\u003c\/h3\u003e\n          \u003cdiv class=\"pillar-desc\"\u003e\n            \u003cp\u003eHigh-speed drilling of the S-Reamer at 800–1,200 RPM (with saline irrigation)\n              enables safe and rapid perforation of the sinus inferior cortical wall without\n              membrane damage. The 'S'-shaped blade design allows the reamer to cut the\n              bone effectively at speed, removing the need for the slow, physically demanding\n              mallet-and-osteotome technique and shortening the operative time significantly.\u003c\/p\u003e\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"feature-block\"\u003e\n        \u003cdiv class=\"feature-media\"\u003e\n          \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/SCA-Features_3.png?v=1785375034\" alt=\"SCA Kit Simple — user-friendly organised kit design reduces technique-sensitivity for sinus crestal elevation\"\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"feature-copy\"\u003e\n          \u003cp class=\"feature-tag\"\u003eSimple\u003c\/p\u003e\n          \u003ch3 class=\"feature-headline\"\u003eUser-friendly design\u003cbr\u003e— reduced technique-sensitivity\u003c\/h3\u003e\n          \u003cdiv class=\"pillar-desc\"\u003e\n            \u003cp\u003eThe SCA Kit provides a much easier and less technique-sensitive approach to\n              sinus crestal elevation. Each component is purpose-designed for a specific\n              step in the procedure sequence, the stopper system controls drilling depth\n              in 1mm increments, and the kit uses a general rotary drilling method that any\n              trained implant surgeon can perform without specialised mallet training.\u003c\/p\u003e\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── TECHNIQUE GUIDE ───────────────────────────────────────── --\u003e\n  \u003cdiv class=\"pd-section pd-section--muted\"\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv class=\"pd-label\"\u003eTechnique Guide\u003c\/div\u003e\n      \u003ch2 class=\"pd-h2\"\u003eStep-by-step procedure sequence\u003c\/h2\u003e\n      \u003cp class=\"pd-lead\"\u003eFrom initial osteotomy preparation through to final implant placement —\n        each SCA Kit component performs a defined role in the crestal elevation sequence.\u003c\/p\u003e\n\n      \u003cdiv class=\"case-block\"\u003e\n        \u003cdiv class=\"case-gallery\" style=\"grid-template-columns: repeat(4, 1fr);\"\u003e\n\n          \u003cdiv class=\"case-img-wrap\"\u003e\n            \u003cdiv class=\"case-step\"\u003e\n              \u003cdiv class=\"case-step-num\"\u003e1\u003c\/div\u003e\n              \u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/SCA_Case_1.png?v=1785375034\" alt=\"SCA Kit Step 1 — Initial Drill and Widening of osteotomy site\"\u003e\u003c\/div\u003e\n            \u003c\/div\u003e\n            \u003cp class=\"case-caption\"\u003e\u003cstrong\u003eInitial Drill \u0026amp; Widening\u003c\/strong\u003e\u003cbr\u003e\n              Drill to 1mm shorter than residual bone height. Widen to final diameter based\n              on bone density. Do not reach within 1mm of the sinus membrane.\u003c\/p\u003e\n          \u003c\/div\u003e\n\n          \u003cdiv class=\"case-img-wrap\"\u003e\n            \u003cdiv class=\"case-step\"\u003e\n              \u003cdiv class=\"case-step-num\"\u003e2\u003c\/div\u003e\n              \u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/SCA_Case_2.png?v=1785375034\" alt=\"SCA Kit Step 2 — S-Reamer drilling remaining bone to inferior cortical wall at 1,200rpm\"\u003e\u003c\/div\u003e\n            \u003c\/div\u003e\n            \u003cp class=\"case-caption\"\u003e\u003cstrong\u003eS-Reamer\u003c\/strong\u003e\u003cbr\u003e\n              Drill remaining bone to the sinus inferior cortical wall. Gently perforate the\n              cortical floor until opening is detected. Speed: 1,200 rpm with irrigation.\u003c\/p\u003e\n          \u003c\/div\u003e\n\n          \u003cdiv class=\"case-img-wrap\"\u003e\n            \u003cdiv class=\"case-step\"\u003e\n              \u003cdiv class=\"case-step-num\"\u003e3\u003c\/div\u003e\n              \u003cdiv\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/SCA_Case_3.png?v=1785375034\" alt=\"SCA Kit Step 3 — Depth Gauge confirming sinus floor perforation and measuring residual bone height\"\u003e\n              \u003c\/div\u003e\n            \u003c\/div\u003e\n            \u003cp class=\"case-caption\"\u003e\u003cstrong\u003eDepth Gauge\u003c\/strong\u003e\u003cbr\u003e\n              Confirm complete sinus floor opening by hanging gauge tip in the sinus wall.\n              Feel membrane with the flat end. Do not insert more than 1mm into sinus.\u003c\/p\u003e\n          \u003c\/div\u003e\n\n          \u003cdiv class=\"case-img-wrap\"\u003e\n            \u003cdiv class=\"case-step\"\u003e\n              \u003cdiv class=\"case-step-num\"\u003e4\u003c\/div\u003e\n              \u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/SCA_Case_4.png?v=1785375034\" alt=\"SCA Kit Step 4 — Bone Carrier delivering 0.05cc bone graft material into osteotome site\"\u003e\u003c\/div\u003e\n            \u003c\/div\u003e\n            \u003cp class=\"case-caption\"\u003e\u003cstrong\u003eBone Carrier\u003c\/strong\u003e\u003cbr\u003e\n              Insert bone graft into the osteotome site using the bone carrier (0.05cc per\n              insertion). Approximately 0.1cc of bone is needed to lift the membrane 1mm.\u003c\/p\u003e\n          \u003c\/div\u003e\n\n          \u003cdiv class=\"case-img-wrap\"\u003e\n            \u003cdiv class=\"case-step\"\u003e\n              \u003cdiv class=\"case-step-num\"\u003e5\u003c\/div\u003e\n              \u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/SCA_Case_5.png?v=1785375034\" alt=\"SCA Kit Step 5 — Bone Condenser pushing graft material to sinus floor\"\u003e\u003c\/div\u003e\n            \u003c\/div\u003e\n            \u003cp class=\"case-caption\"\u003e\u003cstrong\u003eBone Condenser\u003c\/strong\u003e\u003cbr\u003e\n              Push graft material to the sinus floor. Use the wide end for fine particulates\n              and the narrow end for coarse particulates.\u003c\/p\u003e\n          \u003c\/div\u003e\n\n          \u003cdiv class=\"case-img-wrap\"\u003e\n            \u003cdiv class=\"case-step\"\u003e\n              \u003cdiv class=\"case-step-num\"\u003e6\u003c\/div\u003e\n              \u003cdiv\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/SCA_Case_6.png?v=1785375034\" alt=\"SCA Kit Step 6 — Spiral Bone Inserter pushing bone graft into sinus at 80rpm\"\u003e\n              \u003c\/div\u003e\n            \u003c\/div\u003e\n            \u003cp class=\"case-caption\"\u003e\u003cstrong\u003eBone Inserter\u003c\/strong\u003e\u003cbr\u003e\n              Alternative method to push graft into sinus using the spiral bone inserter.\n              Connect stopper (residual alveolar bone height) and rotate at 80 rpm.\u003c\/p\u003e\n          \u003c\/div\u003e\n\n          \u003cdiv class=\"case-img-wrap\"\u003e\n            \u003cdiv class=\"case-step\"\u003e\n              \u003cdiv class=\"case-step-num\"\u003e7\u003c\/div\u003e\n              \u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/SCA_Case_7.png?v=1785375034\" alt=\"SCA Kit Step 7 — Bone Spreader expanding graft laterally at 50-80rpm\"\u003e\u003c\/div\u003e\n            \u003c\/div\u003e\n            \u003cp class=\"case-caption\"\u003e\u003cstrong\u003eBone Spreader\u003c\/strong\u003e\u003cbr\u003e\n              Spread bone laterally to reduce tension against the membrane. Connect stopper\n              and rotate at 50–80 rpm. Repeat after every 0.1cc of bone insertion.\u003c\/p\u003e\n          \u003c\/div\u003e\n\n          \u003cdiv class=\"case-img-wrap\"\u003e\n            \u003cdiv class=\"case-step\"\u003e\n              \u003cdiv class=\"case-step-num\"\u003e8\u003c\/div\u003e\n              \u003cdiv\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/SCA_Case_8.png?v=1785375034\" alt=\"SCA Kit Step 8 — Final Drill freshen-up and implant placement for CMI fixation\"\u003e\n              \u003c\/div\u003e\n            \u003c\/div\u003e\n            \u003cp class=\"case-caption\"\u003e\u003cstrong\u003eFinal Drill \u0026amp; Implantation\u003c\/strong\u003e\u003cbr\u003e\n              Freshen up the channel with a larger drill to remove excess graft material.\n              Place implant and obtain CMI fixation from the sinus inferior cortical wall.\u003c\/p\u003e\n          \u003c\/div\u003e\n\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n\n      \u003cp class=\"kit-note\" style=\"margin-top:20px;\"\u003e\n        Technique guide courtesy of Neobiotech. Select S-Reamer diameter 1mm shorter than\n        estimated residual bone height. Advance depth 1mm per step using 1mm longer stopper\n        for each increment.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── KIT COMPONENTS ───────────────────────────────────────── --\u003e\n  \u003cdiv class=\"pd-section\"\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv class=\"pd-label\"\u003eKit Components\u003c\/div\u003e\n      \u003ch2 class=\"pd-h2\"\u003eComplete instrument set\u003c\/h2\u003e\n      \u003cp class=\"pd-lead\"\u003eEvery instrument required for the full SCA crestal elevation procedure\n        is supplied in a single organised tray — from initial osteotomy through to\n        bone spreading and final implant placement.\u003c\/p\u003e\n\n      \u003cdiv class=\"kit-table-wrap\"\u003e\n        \u003ctable class=\"kit-table\"\u003e\n          \u003cthead\u003e\n            \u003ctr\u003e\n              \u003cth\u003eComponent\u003c\/th\u003e\n              \u003cth\u003eFunction\u003c\/th\u003e\n              \u003cth\u003eKey Spec\u003c\/th\u003e\n            \u003c\/tr\u003e\n          \u003c\/thead\u003e\n          \u003ctbody\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eInitial Drill\u003cbr\u003e\u003cspan style=\"font-size:0.85em; font-weight:400; color:#555;\"\u003eSSD20\u003c\/span\u003e\n\u003c\/td\u003e\n              \u003ctd\u003eCreates guide hole at precise osteotomy point before S-Reamer\u003c\/td\u003e\n              \u003ctd\u003eØ2.0 · 1,200 rpm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eS-Reamer\u003cbr\u003e\u003cspan style=\"font-size:0.85em; font-weight:400; color:#555;\"\u003eICR24 \/ 28 \/ 32 \/ 36\u003c\/span\u003e\n              \u003c\/td\u003e\n              \u003ctd\u003eMain instrument — perforates sinus inferior cortical wall without membrane damage via bone disk\n                mechanism\u003c\/td\u003e\n              \u003ctd\u003eØ2.4 \/ 2.8 \/ 3.2 \/ 3.6 · \u003cbr\u003e800–1,200 rpm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eStopper\u003cbr\u003e\u003cspan style=\"font-size:0.85em; font-weight:400; color:#555;\"\u003eSKS02–SKS11\u003c\/span\u003e\n\u003c\/td\u003e\n              \u003ctd\u003eControls S-Reamer drilling depth in 1mm increments; also used with Bone Spreader and Bone Condenser to\n                prevent membrane rupture\u003c\/td\u003e\n              \u003ctd\u003e10 pieces · \u003cbr\u003e2mm–11mm (1mm steps)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eDepth Gauge\u003cbr\u003e\u003cspan style=\"font-size:0.85em; font-weight:400; color:#555;\"\u003eSDG00\u003c\/span\u003e\n\u003c\/td\u003e\n              \u003ctd\u003eConfirms complete sinus floor perforation and measures residual bone height after S-Reamer\u003c\/td\u003e\n              \u003ctd\u003eSingle instrument · \u003cbr\u003e3 \/ 6 \/ 9 \/ 12mm markings\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eBone Carrier\u003cbr\u003e\u003cspan style=\"font-size:0.85em; font-weight:400; color:#555;\"\u003eJUMBO2\u003c\/span\u003e\n\u003c\/td\u003e\n              \u003ctd\u003eDelivers bone graft material into the osteotome site\u003c\/td\u003e\n              \u003ctd\u003e0.05cc per insertion\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eBone Condenser\u003cbr\u003e\u003cspan style=\"font-size:0.85em; font-weight:400; color:#555;\"\u003eSBC01\u003c\/span\u003e\n\u003c\/td\u003e\n              \u003ctd\u003ePacks graft material onto the sinus floor; wide end for fine particulates, narrow end for coarse\u003c\/td\u003e\n              \u003ctd\u003eØ1.6 \/ Ø2.2\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eSpiral Bone Inserter\u003cbr\u003e\u003cspan style=\"font-size:0.85em; font-weight:400; color:#555;\"\u003eSBI27\u003c\/span\u003e\n\u003c\/td\u003e\n              \u003ctd\u003eAlternative method to push bone graft into sinus after bone carrier placement\u003c\/td\u003e\n              \u003ctd\u003e80 rpm · use with 1mm stopper\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eBone Spreader\u003cbr\u003e\u003cspan style=\"font-size:0.85em; font-weight:400; color:#555;\"\u003eSBS20 \/ SBS30\u003c\/span\u003e\n              \u003c\/td\u003e\n              \u003ctd\u003eSpreads bone graft laterally to reduce membrane tension and increase sinus floor volume\u003c\/td\u003e\n              \u003ctd\u003eØ2.7 \/ Ø3.1 · 50–80 rpm\u003c\/td\u003e\n            \u003c\/tr\u003e\n          \u003c\/tbody\u003e\n        \u003c\/table\u003e\n      \u003c\/div\u003e\n\n      \u003cp class=\"kit-note\" style=\"margin-top:16px;\"\u003e\n        \u003cstrong\u003eS-Reamer diameter selection guide:\u003c\/strong\u003e For 1–3mm sinus insertion depth —\n        Regular fixture: Ø2.4 · Wide fixture: Ø3.2. For more than 4mm insertion depth —\n        Regular fixture: Ø2.8 · Wide fixture: Ø3.6. S-Reamer diameter is directly related\n        to CMI implant diameter and must be selected carefully.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── SPECIFICATIONS ─────────────────────────────────────────── --\u003e\n  \u003cdiv class=\"pd-section pd-section--muted\"\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv class=\"pd-label\"\u003eSpecifications\u003c\/div\u003e\n      \u003ch2 class=\"pd-h2\"\u003eTechnical specifications\u003c\/h2\u003e\n\n      \u003ctable class=\"spec-table\"\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eDevice type\u003c\/td\u003e\n          \u003ctd\u003eSinus Crestal Approach Kit — transcrestal sinus elevation surgical instrument set\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eMaterial\u003c\/td\u003e\n          \u003ctd\u003eMedical grade stainless steel (surgical tools and drivers)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eS-Reamer diameters\u003c\/td\u003e\n          \u003ctd\u003eØ2.4 (ICR24) · Ø2.8 (ICR28) · Ø3.2 (ICR32) · Ø3.6 (ICR36)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eS-Reamer operating speed\u003c\/td\u003e\n          \u003ctd\u003e800–1,200 rpm with saline irrigation\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eStopper range\u003c\/td\u003e\n          \u003ctd\u003e2mm–11mm (10 pieces, SKS02–SKS11) — 1mm increment steps\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eBone Spreader \/ Inserter speed\u003c\/td\u003e\n          \u003ctd\u003e50–80 rpm\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eBone Carrier volume\u003c\/td\u003e\n          \u003ctd\u003e0.05cc per insertion\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eSterilisation\u003c\/td\u003e\n          \u003ctd\u003eSteam autoclave — Pre-vacuum: 132°C \/ 2 bar \/ 3 min \/ 30 min dry · Gravity: 121°C \/ 1 bar \/ 40 min \/ 30\n            min dry\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eSterility\u003c\/td\u003e\n          \u003ctd\u003eNon-sterile medical device — must be sterilised before and after each procedure\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eManufacturer\u003c\/td\u003e\n          \u003ctd\u003eNeobiotech Co., Ltd — Seoul, Korea\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eOrigin\u003c\/td\u003e\n          \u003ctd\u003eMade in Korea\u003c\/td\u003e\n        \u003c\/tr\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── CLINICAL TIPS ──────────────────────────────────────────── --\u003e\n  \u003cdiv class=\"pd-section\"\u003e\n    \u003cdiv class=\"pd-inner\"\u003e\n      \u003cdiv class=\"pd-label\"\u003eClinical Tips\u003c\/div\u003e\n      \u003ch2 class=\"pd-h2\"\u003eGetting the most from the SCA Kit\u003c\/h2\u003e\n      \u003cp class=\"pd-lead\"\u003ePractical guidance for safe, predictable crestal sinus elevation with\n        the SCA Kit.\u003c\/p\u003e\n\n      \u003cdiv class=\"tips-list\"\u003e\n\n        \u003cdiv class=\"tip-item\"\u003e\n          \u003cdiv class=\"tip-num\"\u003e1\u003c\/div\u003e\n          \u003cdiv class=\"tip-body\"\u003e\n\u003cstrong\u003eSelect S-Reamer diameter based on fixture size — not just residual\n              bone.\u003c\/strong\u003e\n            S-Reamer diameter directly determines CMI fixation and must match the planned\n            implant diameter. For regular fixtures: Ø2.4 (1–3mm insertion into sinus) or\n            Ø2.8 (more than 4mm). For wide fixtures: Ø3.2 or Ø3.6 respectively. An\n            undersized reamer risks inadequate CMI fixation; an oversized reamer increases\n            membrane perforation risk.\u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"tip-item\"\u003e\n          \u003cdiv class=\"tip-num\"\u003e2\u003c\/div\u003e\n          \u003cdiv class=\"tip-body\"\u003e\n\u003cstrong\u003eAdvance drilling depth 1mm at a time — not in one pass.\u003c\/strong\u003e\n            The stopper system is designed for 1mm incremental progression. Confirm the\n            Valsalva test (patient blows nose with mouth closed) after each increment to\n            check membrane integrity before advancing to the next stopper size. This step-by-step\n            approach is the single most effective safety measure in the SCA Kit protocol.\u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"tip-item\"\u003e\n          \u003cdiv class=\"tip-num\"\u003e3\u003c\/div\u003e\n          \u003cdiv class=\"tip-body\"\u003e\n\u003cstrong\u003eUse the depth gauge to confirm — not to measure.\u003c\/strong\u003e\n            The depth gauge confirms complete opening of the sinus floor by hanging its\n            tip on the inner sinus wall. Feel for the membrane with the flat end of the\n            gauge. Do not insert the depth gauge more than 1mm beyond the residual bone\n            height — the purpose is sinus floor confirmation, not further membrane\n            elevation.\u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"tip-item\"\u003e\n          \u003cdiv class=\"tip-num\"\u003e4\u003c\/div\u003e\n          \u003cdiv class=\"tip-body\"\u003e\n\u003cstrong\u003ePlan bone volume based on the elevation height required.\u003c\/strong\u003e\n            Approximately 0.1cc of bone graft material is required to lift the membrane\n            1mm in height. For lateral expansion, insert at least 0.3cc before starting\n            bone spreading. Use the narrow bone spreader (SBS20 Ø2.7) for 2.4–2.8mm\n            S-Reamer cases and the wide spreader (SBS30 Ø3.1) for 3.2–3.6mm cases. Spread\n            after every 0.1–0.2cc insertion to expand the membrane progressively.\u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"tip-item\"\u003e\n          \u003cdiv class=\"tip-num\"\u003e5\u003c\/div\u003e\n          \u003cdiv class=\"tip-body\"\u003e\n\u003cstrong\u003eUse a freshen-up drill before final implant placement.\u003c\/strong\u003e\n            After completing bone grafting, freshen the channel with a slightly larger\n            diameter drill to remove excess graft material from the osteotomy walls.\n            This ensures clean cortical engagement at fixture placement, reduces the\n            chance of graft material being forced laterally during implant insertion,\n            and supports the CMI fixation achieved from the sinus inferior cortical wall.\u003c\/div\u003e\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"tip-warn\"\u003e\n        \u003cstrong\u003e⚠ Clinical Notice:\u003c\/strong\u003e The SCA Kit is a non-sterile medical device intended\n        for use by dental surgeons who have completed implant procedure training. The kit must be\n        sterilised by steam autoclave before and after each procedure. Hydrogen peroxide is\n        prohibited for cleaning — it damages the TIN coating and laser markings. Do not use in\n        patients with uncontrolled systemic disease, active infection, malignancy under radiation\n        treatment, blood clotting disorders, titanium allergy, or unrealistic treatment\n        expectations. Follow AS\/NZS sterilisation guidelines. Refer to the Instructions for Use\n        for full indications, contraindications, and handling guidelines.\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e","brand":"Neobiotech","offers":[{"title":"Default Title","offer_id":49138078155042,"sku":"SCAKIT","price":3500.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/SCA.png?v=1732060656","url":"https:\/\/xdentalsupplies.com.au\/products\/sinus-crestal-approach-kit","provider":"X Dental Supplies","version":"1.0","type":"link"}