{"product_id":"universal-screw-removal-kit-surgident","title":"Surgident Universal Screw Removal Kit","description":"\u003cp\u003e\u003cstrong\u003eUniversal Screw Removal Kit - SURGIDENT®\u003c\/strong\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA variety of screw removal instruments are included which allow clinicians to remove both fractured and stripped prosthetic screws. This kit provides everything.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003eScrew Removal Components\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProsthetic guide holder\u003c\/li\u003e\n\u003cli\u003eLong ratchet wrench\u003c\/li\u003e\n\u003cli\u003eAdapter (contra Angle to 4mm square)\u003c\/li\u003e\n\u003cli\u003eReverse drills\u003c\/li\u003e\n\u003cli\u003eReverse taps\u003c\/li\u003e\n\u003cli\u003eFlat tip driver\u003c\/li\u003e\n\u003cli\u003eProsthetic guides (listed below)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003eExternal Mini (M)\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHi-Tec Summit\u003c\/li\u003e\n\u003cli\u003eNobel Biocare Branemark System NP\u003c\/li\u003e\n\u003cli\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOcta Internal (O)\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHi-Tec Tite-Fit \u0026amp; Tapered Tite-Fite\u003c\/li\u003e\n\u003cli\u003eStraumann ITI Tissue Level\u003c\/li\u003e\n\u003cli\u003eImplant Direct SwishPlant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003eTSV 3.7I4.1\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHi-Tec Logict, Spark, Self-Thread\u003c\/li\u003e\n\u003cli\u003eBioHorizons Tapered Internal 3.7 and 4.70\u003c\/li\u003e\n\u003cli\u003eImplant Direct Legacy (3.7 and 4.7 internal hex)\u003c\/li\u003e\n\u003cli\u003eMIS 3.3. 3.75. and 4.20\u003c\/li\u003e\n\u003cli\u003eZimmer TSV 3.7. 4.1 and 4.70\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003eExternal Regular (W)\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNobel Biocare Branemark System RPO\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003eHex Submerged (H)\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHi-Tec Logic, Implex, ExpertNL\u003c\/li\u003e\n\u003cli\u003eNobel Biocare NobelActive\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003eTrilobe 3.5 NP\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHi-Tec Vision@ 3,5\u003c\/li\u003e\n\u003cli\u003eNobel Biocare Tri Lobe@ 3.5\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstructions for Stripped Screw Removal\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eStripped screws are generally more difficult to remove than fractured screws because fractured screws are not under compression. The most effective method of removing a stripped screw is to create a flathead channel with a round bur, and then use a flat head driver to reverse the screw out of position.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003eStep 1\u003cbr\u003e\u003c\/strong\u003eUsing a 1\/2 round bur in a high-speed handpiece, create a channel on the head of the screw across the diameter of the head, creating a flat head.\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStep 2\u003cbr\u003e\u003c\/strong\u003eAfter the channel is created, use the FTD-01 and ratchet wrench to back the screw out.\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003eInstructions for Fractured Screw Removal\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eStep 1\u003cbr\u003e\u003c\/strong\u003ePress the remover drill (D-REM) in the reverse direction (under 80rpm) on the top of the fractured screw to reverse the screw fragment out of the screw channel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStep 2\u003c\/strong\u003e\u003cbr\u003eIf the remover drill is unsuccessful: Use the provided guide information to select the correct prosthetic guide -based on the implant platform.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStep 3\u003c\/strong\u003e\u003cbr\u003eAttach the selected guide to the guide handle and engage the connection within the implant.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStep 4\u003cbr\u003e\u003c\/strong\u003eWith your handpiece in reverse (1,200-1,300 rpm); create a divot in the top of the screw with the D-REM.\u003c\/p\u003e\n\u003cp\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/xas5NsGZ5LA?si=0l6fcodZUTAr2V_z\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" allowfullscreen=\"\"\u003e\u003c\/iframe\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e","brand":"Surgident","offers":[{"title":"Default Title","offer_id":49137964843298,"sku":"SD-SR","price":1300.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0900\/3588\/0226\/files\/SDSR.png?v=1732278820","url":"https:\/\/xdentalsupplies.com.au\/products\/universal-screw-removal-kit-surgident","provider":"X Dental Supplies","version":"1.0","type":"link"}