NeoBiotech Universal Prosthetic Kit

NeoBiotech Universal Prosthetic Kit

Regular price $2,300.00
Regular price Sale price $2,300.00
Sale Sold out
View full details
Neobiotech Universal Prosthetic Kit — prosthetic drivers compatible with major implant brands
Neobiotech · Prosthetic Solution

Universal
Prosthetic Kit

A complete set of prosthetic drivers compatible with Straumann, Nobel Biocare, Osstem, Zimmer, Astra, Neobiotech, and more, covering the implant brands most commonly encountered in Australian dental practice, in a single organised tray. No need to purchase separate driver kits for each system. Four driver types, two lengths each, plus a Driver Holder and Torque Ratchet for a complete chairside prosthetic workflow.

Straumann · Nobel · Osstem · Zimmer · Astra & More One Kit — No Per-Brand Driver Sets Required Driver Holder · Torque Ratchet Included
Clinical Insight

What clinicians are saying

Real-world feedback from implantologists and prosthodontists using the Universal Prosthetic Kit in multi-brand practice environments.

"In my practice I see patients who've had implants placed elsewhere — Straumann, Nobel, Osstem, you name it. Before this kit I was constantly checking which driver set to pull out of the cupboard, or worse, realising mid-appointment that I didn't have the right one. Having all four driver types in one tray has completely removed that problem. It sounds like a small thing, but it adds up to real time saved across a full day of restorative appointments."

Multi-Brand · Workflow Efficiency · Restorative Practice

"The economics of maintaining separate prosthetic driver kits for every implant brand your patients might present with is genuinely significant — especially when patients transfer from interstate or overseas. The Universal Prosthetic Kit covers Straumann SCS, Nobel Unigrip, and all the standard hex connections in one set that lives permanently on my prosthetic tray. It's paid for itself many times over."

Cost Efficiency · SCS · Unigrip · Multi-Brand Coverage
Indications

When to use the Universal Prosthetic Kit

Indicated for all prosthetic stages of implant treatment where abutment or screw tightening and removal is required. One kit eliminates the need to purchase and maintain separate driver sets for each implant brand in your practice.

Cover Screw Placement and Removal — Connecting and detaching cover screws at implant placement and second-stage surgery, across all compatible implant systems.
Abutment Screw Tightening — Final seating and torque-controlled tightening of abutment screws at the restorative stage, using the Torque Ratchet for accurate torque delivery.
Healing Abutment Connection — Placing and retrieving healing abutments at second-stage surgery, using the Driver Holder for intraoral access.
Multi-Brand Practice Environments — A single Universal Prosthetic Kit covers the driver requirements for major implant systems including Straumann, Nobel Biocare, Osstem, Southern Implants, and more, removing the need to purchase and maintain separate per-brand driver kits.
Upper Structure Connection and Removal — Connecting or detaching any other upper prosthetic structures placed on the implant fixture, at any stage of implant treatment.
Torque Verification and Re-tightening — Recall and maintenance appointments where abutment or prosthetic screw torque is verified or re-applied using the Torque Ratchet Wrench.
Kit Components

Complete instrument set

All prosthetic drivers, a Driver Holder, and a Torque Ratchet — supplied in a single organised tray (Neo Universal Prosthetic Kit Ver.0).

Universal Prosthetic Kit tray — 4 driver types in 10mm and 15mm, Torque Ratchet Wrench, and Driver Holder

1. Driver

Used to tighten an abutment or abutment screw. Each driver type is supplied in both 10mm (short) and 15mm (long) versions.

Driver Type Key Spec Compatible Implant Systems
1.2 Hex Driver (0.48")
HD1210S · HD1215S
10mm · 15mm Neobiotech / Biomet 3i / Dentsply-Friadent / Xive / Osstem / DIO / Megagen
1.25 Hex Driver (0.5")
HD12510S · HD12515S
10mm · 15mm Biohorizons / Zimmer / Astra / Implant Direct Legacy / Camlog / MIS / Dentis / Dentium
SCS Driver
WSCSD10S · WSCSD15S
10mm · 15mm Straumann / Implant Direct Replant
Unigrip Driver
WUGD10S · WUGD15S
10mm · 15mm Nobel Biocare / Implant Direct Swishplait / Southern Implants / Neoss

2. Driver Holder  DH01

Connects to various prosthetic drivers to allow easy intraoral handling of healing cover screws and abutment screws. Features a swivel hole for added maneuverability and a hex driver end for direct use.

Universal Prosthetic Kit Driver Holder DH01 — swivel hole and hex driver end

3. Torque Ratchet  TW60

Tightens the hex driver and measures torque. By changing the direction of the tip, tightening and loosening can be controlled independently.

Universal Prosthetic Kit Torque Ratchet TW60 — T-bar handle with torque measurement scale and direction selector
Specifications

Technical specifications

Device type Universal prosthetic driver kit for implant abutment and screw tightening
Material Medical grade titanium and stainless steel
Driver types 1.2 Hex (0.48") · 1.25 Hex (0.5") · SCS · Unigrip
Driver lengths 10mm (short) · 15mm (long), both supplied per driver type
Sterility Non-sterile medical device — must be sterilised by autoclave before and after each procedure
Sterilisation (Pre-Vacuum) 132°C · 2 bar · 3 min exposure · 30 min dry
Sterilisation (Gravity) 132°C · 1 bar · 40 min exposure · 30 min dry
Manufacturer Neobiotech Co., Ltd, Seoul, Korea
Origin Made in Korea
Operating Tips

Getting the most from the Universal Prosthetic Kit

Practical guidance for chairside prosthetic procedures using the Universal Prosthetic Kit.

1
Confirm driver compatibility before each case. Select the driver type that matches the implant system being restored. Use the compatibility list as a reference if there is any uncertainty. Using an incorrect driver size risks stripping the abutment screw head, which can make screw removal difficult or impossible without specialist intervention.
2
Use the 10mm (short) driver for posterior access. The 15mm long driver provides better torque transmission when used with the Torque Ratchet. In posterior sites with limited vertical access, the 10mm driver reduces the risk of the driver disengaging mid-tightening. For most anterior abutment tightening, the 15mm driver combined with the Driver Holder gives the best control.
3
Use the Driver Holder for all intraoral cover screw and healing abutment work. The Driver Holder connects to any driver in the kit and allows precise intraoral manipulation of cover screws and healing abutments without dropping. The swivel hole allows the angle to be adjusted for difficult access sites, which is particularly useful in second-stage surgery where visibility is limited by soft tissue.
4
Apply final torque with the Torque Ratchet — not finger pressure alone. The Torque Ratchet (TW60) allows the direction of tightening and loosening to be selected independently by changing the tip direction. Always use the ratchet for final abutment screw torque. The scale provides a reference for confirming correct torque delivery, reducing the risk of under-tightening (screw loosening in function) or over-tightening (screw fracture).
5
Sterilise the full kit before and after each patient procedure. All instruments in the Universal Prosthetic Kit are non-sterile medical devices and must be sterilised by autoclave before use and after each procedure. Recommended autoclave conditions: Pre-Vacuum 132°C / 2 bar / 3 min exposure / 30 min dry, or Gravity 132°C / 1 bar / 40 min exposure / 30 min dry. After use, detach each component, wash promptly, dry thoroughly, and store at room temperature away from soiled areas before re-sterilising.
⚠ Clinical Notice: The Universal Prosthetic Kit is a non-sterile medical device intended for use by trained dental surgeons and prosthodontists. The kit must be sterilised by autoclave before and after each patient procedure. Use only with compatible implant systems as listed in the product compatibility guide. Follow AS/NZS sterilisation and infection control guidelines. Refer to the product Instructions for Use for full indications, contraindications, and handling instructions.